PLZ-5W 3

Connecting the Power Cord

WARNING

Risk of electric shock.

• The PLZ-5W conforms to IEC Safety Class I (equipment 

that has a protective conductor terminal). Be sure to 

earth ground the product to prevent electric shock.

• The PLZ-5W is grounded through the power cord 

ground wire. Connect the protective conductor terminal 

to earth ground.

─ Note ─

• Use the supplied power cord to connect to the AC line. If the 

supplied power cord cannot be used because the rated voltage 

or the plug shape is incompatible, have a qualified engineer 

replace it with an appropriate power cord that is 3 m or less in 

length. If obtaining a power cord is difficult, contact your Kikusui 

agent or distributor.

• The power cord with a plug can be used to disconnect the 

PLZ-5W from the AC power line in an emergency. Connect the 

plug to an easily accessible power outlet so that the plug can be 

removed from the outlet at any time.

• Secure adequate space around the power cord plug. Do not 

insert the power cord plug into an outlet that is difficult to ac

-

cess or place objects around the power cord plug that will make 

plugging and unplugging difficult.

• Do not use the supplied power cord with other instruments.

The PLZ-5W conforms to IEC Overvoltage Category II 

(energy-consuming equipment that is supplied from a fixed 

installation).

 

Turn the POWER switch off ( ).

 

Check that the AC power line meets the nominal 

input rating of the PLZ-5W.

The PLZ-5W can receive a nominal line voltage in the range 

of 100 Vac to 240 Vac at 50 Hz or 60 Hz.

 

Connect the power cord to the AC INPUT inlet on 

the rear panel.

 

Connect the power cord plug to a properly 

grounded outlet.

Safety Precautions

When using this product, be sure to observe the “Safety 

Precautions” in the Safety information manual. The follow-

ing precautions pertain only to this product.

•  The rear panel may become hot during operation. If you 

touch it, you may burn yourself. 

Precautions Concerning 

Installation Location

When installing this product, be sure to observe the 

“Precautions Concerning Installation Location” in the 

Safety information manual. The following precautions per-

tain only to this product.

•  When installing this product, be sure to observe the tempera-

ture and humidity ranges indicated below.
Operating temperature range: 0 °C to 40 °C
Operating humidity range: 20 %rh to 85 %rh (no 

condensation)

•  When storing this product, be sure to observe the tempera-

ture and humidity ranges indicated below.
Storage temperature range: -20 °C to 70 °C
Storage humidity range: 90 %rh or less (no condensation)

•  Do not install the product vertically.

It may cause injury to the operator or damage to the product 

when it falls down.

Summary of Contents for PLZ1205W

Page 1: ...ved from 1 5 V to 1 0 V offering support of low voltage input Arbitrary I V characteristics mode Arbitrary I V characteristics mode that allows current to be set arbitrarily in relation to voltage inp...

Page 2: ...e of how to control measuring instruments using a personal computer Quick reference This document briefly explains the control panel and the basic operation of it Safety information This document cont...

Page 3: ...ge Category II energy consuming equipment that is supplied from a fixed installation 1 Turn the POWER switch off 2 Check that the AC power line meets the nominal input rating of the PLZ 5W The PLZ 5W...

Page 4: ...nt flows and the voltage at the load input terminals may fall below the minimum operating voltage of the PLZ 5W Using the following table as a reference select wiring whose nominal cross sectional are...

Page 5: ...her There are two available positions Use the appropriate position for the load cables that you are using For cables up to 10 mm Put the top and bottom load input terminal covers together so that the...

Page 6: ...erminal on the front panel to the negative polarity of the DUT Connecting the Sensing Cables To perform remote sensing connect the sensing cables A voltage measurement point can be changed from a load...

Page 7: ...e PLZ 5W remotely by sending commands For details on remote control see the Communication Interface Manual on the included CD ROM The following environment is required to view the Communication Interf...

Page 8: ...demarks or trademarks of Microsoft Corporation in the United States and or other countries Other company names and product names used in this manual are generally trademarks or registered trademarks o...

Reviews: