Parts Names and Functions 5-3
RANGE (SHIFT, 7) key
Selects output voltage range.
The “100V” indication in the RANGE area lights up when equip-
ment is in the 100V range, “200V” lights up when it is in the 200V
range.
When the RANGE key is pressed, the range indication to be
selected blinks. Press the ENTER key to con
fi
rm the mode selec-
tion.
AC/DC (SHIFT, 8) key
Switches the mode among the AC, AC-S, and DC modes. The “AC”
indication in the MODE area lights up in the AC mode, the “AC-S”
indication in the MODE area lights up in the AC-S mode, and the
“DC” indication in the MODE area lights up in the DC mode.
When the AC/DC key is pressed, the mode to be selected blinks.
Press the ENTER key to con
fi
rm the mode selection.
DIGIT (SHIFT, .) key
Selects the digit mode that enables a speci
fi
ed or higher digits to
change in the voltage setting or frequency setting mode.
In the digit mode, the digit selected in the 7-segment LEDs becomes
brighter, enabling modi
fi
cation of the selected and higher digits (to
the left of that selected).
[7] CLR key
Cancels the set value and recalls the previous value.
[8] MEM key
Calls voltage (and frequency) value (or values) from the memory.
Pressing the MEM key and then selecting a memory address using
the numeric keys or rotary encoder will cause the voltage and fre-
quency values stored in that address to be read. Pressing the V key
in the voltage setting mode causes the voltage value to be displayed,
while pressing the F key in the frequency setting mode causes the
frequency value to be displayed.
Press the ENTER key to set the voltage and frequency retrieved in
the output mode.