4-2 Operation Method
RC03-PCR-LA
Switching the Voltage Display Mode
To switch the voltage display mode on the Remote Controller, press
the Vrms/Vset (SHIFT, V) key in the Home Position.
Change to the Current Display Mode
To enter the current measurement mode, press the I key in the Home
Position.
Memory Function
The RC03-PCR-LA Remote Controller allows read only operation.
Data in memory addresses 0 to 9 can be read by following the same
procedure as that performed with the PCR-LA power supply. To write
data into the memory, perform operations from the PCR-LA power
supply control panel or through the GPIB or RS-232C interface.
Memory Read Procedure
Select the same output voltage mode (AC, DC, or AC + DC) as that
used when setting the memory. To read the contents stored at each
address (“ADRS”), follow the procedure speci
fi
ed below.
1. Press the ESC key to select the Home Position.
2. Press the MEM key to light up the MEM LED.
3. Enter a memory address using the numeric keys or rotary
encoder.
The memory address entered will be indicated in the rightmost
area of the 7-segment LEDs.
Fig.4-1
Displaying a Memory Address
This causes the set value stored in the entered memory address to
be read.
Pressing the V key in the voltage setting mode causes a voltage
value to appear on the 7-segment LED, while pressing the F key
in the frequency setting mode causes a frequency value to appear.
To return the memory address display, press the ESC or MEM
key.
4.
To con
fi
rm the read value, press the ENTER key. To cancel it,
press the ESC key.
This allows you to exit the memory address display.