54
DSI1020/ DSI3020
Appendix A AC Power Supply Connection Diagram
Three PCR-LE DSI3020
The PCR-LE with the U-phase board will be the master unit controlling the other two PCR-
LEs. It is convenient to place the U-phase PCR-LE in an easy-to-operate location.
As shown in example 1, the U-phase unit must be located in the center when connecting the
cables supplied with the three-phase output driver (3P05-PCR-LE).
To connect as shown in example 2, you need the option cable (150 cm/280 cm) for the 3P05-
PCR-LE.
SLOT3
SLOT3
SLOT3
SLOT1
SLOT1
OUTPUT
G N L
OUTPUT
G N L
OUTPUT
G N L
PCR-LE series
AC power supply
(U-phase unit)
PCR-LE series
AC power supply
(V-phase unit)
PCR-LE series
AC power supply
(W-phase unit)
DSI3020 Dip Simulator
SLOT4
SLOT4
SLOT4
SLOT2
SLOT2
SLOT2
SLOT1
Use the communication interface of the U-phase
unit.
To use GPIB, USB, or LAN, install the appropriate
board in SLOT4 of the U-phase unit.
To use RS-232C, use the RS-232C terminal on
the front panel of the U-phase unit.
Install the optional three-phase output drivers (3P05-PCR-LE) in SLOT1
of the U-phase unit, V-phase unit, and W-phase unit.
Install the control board
supplied with this
product in SLOT3 of
the U-phase unit.
AUX
PHASE IN
G N W N V N U
G N W V U
Connect to the EUT
or relay terminals.
INPUT
OUTPUT
To the PC
(GPIB, USB,
or LAN)
To the PC (RS-232C)
4
5
6
7
8
9
10
11
12
3
2
1
1P2W
1P3W
3P3W
3P4W
Connectable EUT input circuits
U
V
W
V
U
W
Example 1
Example 2
Summary of Contents for DSI1020