1
Example of connection with external devices
This product receives input signals from an encoder, a photocell sensor, etc. to make settings for printing.
It receives an input signal as a trigger from a photocell sensor, calculates the timing of printing, and prints
characters on a workpiece.
If the line speed is not constant, it receives a signal from an encoder to adjust the timing of printing.
Based on input/output signals from a PC and a PLC, the whole line can be systematized.
In addition, when a signal lamp is connected, an error can be visually output.
For the connection and setting of these devices, refer to the separate instruction manuals: "I/O,"
"Communication," and "Operation/Maintenance."
Encoder
Signal lamp
Photoelectric sensor
Main unit
Printhead
PLC
UPS
Workpiece
Conveyor