23
1-4 Installation and connection
Installation
Power and environment
Memo
The AC outlet shall be installed near the equipment and shall be easily accessible.
This product is also designed for IT power distribution system with phase-to-phase voltage
230V.
Ambient operating temperature varies depending on ink type. For details, refer to the sepa-
rate "Ink compatibility table".
Power supply
Rated power supply voltage
90 to 265 VAC, 47 to 63 Hz
Power consumption
80 W
Grounding
Class D ground
Operating
environment
Ambient operating temperature 0 to 40 [
°
C]
Ambient operating humidity
10 to 85 [%] (non-condensing)
Operating environment
Main unit
- Flat place
- Place without high heat sources
- Place that is not subject to rapid temperature changes
- Place that is not subject to vibrations
- Place that is not exposed to dust or oil
- Well-ventilated place
Printhead
- Place without high heat sources
- Place that is not subject to rapid temperature changes
- Place that is not subject to vibrations
- Place that is not exposed to dust or oil
Summary of Contents for CCS3000L
Page 9: ...9 ...
Page 37: ...37 ...
Page 59: ...59 ...
Page 61: ...61 5 2 Printhead 60 φ49 2 21 197 17 7 140 54 3 20 59 4 30 63 55 φ 2 0 Unit mm ...