Keysight N5990A-155 DisplayPort User Guide
91
Sink Calibration Procedures
5
• Result (Pass / Fail): “Pass” indicates that the test is successful.
• Sinusoidal Jitter Frequency: Shows the frequency of the Sinusoidal
Jitter used for this point.
• Max. Passed SJ: Maximum SJ amplitude where the device passed the
test.
• Min. Spec.: Minimum SJ amplitude for this frequency specified in the
CTS.
• Jitter Capability Test Setup: Maximum possible jitter of the instruments
being used in the setup.
• Max. Applied SJ Jitter: Maximum jitter that was applied to the DUT
during the test.
• Generator Limit Reached: Determines whether the test for this
frequency was stopped owing to the instrument limitation or to the
device failing this amplitude.
Summary of Contents for N5990A-155
Page 1: ...User Guide Keysight N5990A 155 DisplayPort...
Page 6: ...6 Keysight N5990A 155 DisplayPort User Guide Contents...
Page 7: ...Keysight N5990A 155 DisplayPort User Guide 1 Introduction Overview 8 Document History 9...
Page 10: ...10 Keysight N5990A 155 DisplayPort User Guide 1 Introduction...
Page 79: ...Keysight N5990A 155 DisplayPort User Guide 5 Receiver Tests DisplayPort Receiver Tests 83...
Page 104: ...104 Keysight N5990A 155 DisplayPort User Guide 5 Sink Calibration Procedures...
Page 105: ...Keysight N5990A 155 Display Port User Guide 105...