Keysight PXI General Purpose Switch Modules Startup Guide

Module Front Panel Connectors And System Connections

M9130A PXI SPDT Switch: 26 channels

The M9130A is an array of 26 single pole, double throw (Form C) relays. In the 

default (not energized) state, all signal paths are between the COM terminal and 

the corresponding Normally Closed (NC) terminal. Energizing a relay disconnects 

the NC terminal and creates a signal path between the COM and NO terminals. 
The module is a general purpose armature relay module. They are suitable for 

use where reed relay based switching modules do not have sufficient voltage or 

current carrying capability. Applications include the switching of medium power 

AC and DC loads, or slave switching larger relays or solenoids. Connections are 

made to the module via a front panel mounted 78 pin D-Type connector plug. 
 

M9130A Connector Pinout 

Figure 2 and the associated table lists the front 

panel 78 pin D male connector (viewed from the module front panel) and pin 

connections. Table 1 lists the pin out by channel number.

Summary of Contents for M9130A

Page 1: ...Keysight PXI General Purpose Switch Modules M9130A M9131A M9132A M9133A M9135A Startup Guide...

Page 2: ......

Page 3: ...T NOTICE IN FUTURE EDI TIONS FURTHER TO THE MAXIMUM EXTENT PERMITTED BY APPLICABLE LAW KEYSIGHT DISCLAIMS ALL WAR RANTIES EITHER EXPRESS OR IMPLIED WITH REGARD TO THIS MANUAL AND ANY INFORMATION CONTA...

Page 4: ...rform proce dures involving cover or shield removal unless you are qualified to do so DO NOT operate damaged equipment Whenever it is possible that the safety protection features built into this prod...

Page 5: ...ltage or have additional insulation added rated for the maximum voltage and will be isolated from conductive parts using a thermal compound or tape rated for the maximum voltage applied Do not mount m...

Page 6: ...Aus tralia EMC Framework regulations under the terms of the Radio Commu nication Act of 1992 ICES NMB 001 indicates that this ISM device complies with the Canadian ICES 001 This symbol represents the...

Page 7: ...Keysight IO Libraries Connection Expert 18 Verify operation 19 Characteristics 19 Default Path Settings 20 Module Functional Description 20 Module Programming 21 Identifying Channel Numbers 22 Module...

Page 8: ...vii Keysight PXI General Purpose Switch Modules Startup Guide High Energy Sources 45 Environmental Operating Conditions 46...

Page 9: ...es M9130A PXI SPDT Switch 26 channels Armature Relays M9131A PXI SPDT Switch 64 channels Reed Relays M9132A PXI SPST Switch 50 channels Reed Relays M9133A PXI SPST Switch 100 channels Reed Relays M913...

Page 10: ...onic assemblies should be performed at a static safe work station The following figure shows an example of a static safe work station using two types of ESD protection Purchase acceptable ESD accessor...

Page 11: ...to the Support information on the product web page at www keysight com find pxiswitch 3 Write the following information on a tag and attach it to the malfunctioning equipment Name and address of owner...

Page 12: ...ct printed documentation in PDF format for the PXI General Purpose switch modules An Automation Ready CD with Keysight IO Libraries Suite version 16 0 or later Any other accessories that you ordered c...

Page 13: ...eater recommended 1 GB minimum 1 GB minimum Available hard disk space 1 5 GB available hard disk space includes 1GB available for Microsoft NET Framework 3 5 SP1 100MB for Keysight IO Libraries Suite...

Page 14: ...onnection Expert the IVI Shared Components and the VISA Shared Components 1 Insert the Automation Ready CD with Keysight IO Libraries Suite into the CD ROM drive of your system controller Wait a few s...

Page 15: ...modules using Microsoft development environments e g Visual Studio C C C Visual Basic Keysight VEE MATLAB or National Instruments LabVIEW Accept the license terms and click Next Keysight Software Lice...

Page 16: ...he laptop With a Keysight Y1200A cable connect the adapter to the System Interface module on the PXI chassis Using an embedded computer Refer to the figure above If you are using an embedded controlle...

Page 17: ...lot by placing the module card edges into the front module guides top and bottom Slide the module to the rear of the chassis Ensure that the injector ejector handle is pushed down in the unlatched dow...

Page 18: ...nt desktop or laptop PC power on the computer Choose the default option for any Found New Hardware dialogs Chassis Power Down Process If you are using a remote controller linked to the M9021A Cable In...

Page 19: ...iguration In the Windows Notification Area click the IO icon then click Keysight Connection Expert Locate your interfaces and instruments in the Keysight Connection Expert Explorer Pane The following...

Page 20: ...e SFP enters it s monitor mode In this mode you cannot change relay state and the menu buttons are grayed out However as the other application controls the channels the SFP interface monitors and disp...

Page 21: ...odules use this supply 5Vdc 12Vdc ground as well as the control signals from the chassis backplane The relay drivers are activated by the PCI Bridge U1 via output registers There are no user serviceab...

Page 22: ...Many methods in the IviSwtch interfaces accept a channel string parameter The channel names supported by the AgMSwitch driver depend upon the specific switch module to which the driver is connected In...

Page 23: ...where chn is the actual channel number For example RouteCloseChannel ch8 will close the relay that connects channel 8 COM common to it s NO Normally Open terminal The following graphic shows the Soft...

Page 24: ...between the COM and NO terminals The module is a general purpose armature relay module They are suitable for use where reed relay based switching modules do not have sufficient voltage or current carr...

Page 25: ...6 COM 48 Ch 13 COM 78 Ch 20 COM 30 Ch 26 COM 39 CH 6 NO 67 CH 13 NO 58 CH 20 NO 10 CH 26 NO 19 Ch 6 NC 68 Ch 13 NC 59 Ch 20 NC 11 Ch 26 NC 20 Ch 7 COM 69 Ch 14 COM 21 CH 7 NO 49 CH 14 NO 1 All pins a...

Page 26: ...al Energizing a relay disconnects the NC terminal and creates a signal path between the COM and NO terminals The modules uses reed relays Ruthenium sputtered type that offer very long life with good l...

Page 27: ...NC 130 Ch 26 NC 71 Ch 27 NC 30 Ch 28 NC 172 Ch 29 NO 129 Ch 30 NO 72 Ch 31 NO 29 Ch 32 NO 173 Ch 29 COM 128 Ch 30 COM 73 Ch 31 COM 28 Ch 32 COM 174 Ch 29 NC 127 Ch 30 NC 74 Ch 31 NC 27 Ch 32 NC 175 C...

Page 28: ...NC 56 Ch 23 NC 68 Ch 39 NC 80 Ch 55 NC 92 Ch 8 COM 46 Ch 24 COM 34 Ch 40 COM 22 Ch 56 COM 10 Ch 8 NO 47 Ch 24 NO 35 Ch 40 NO 23 Ch 56 NO 11 Ch 8 NC 45 Ch 24 NC 33 Ch 40 NC 21 Ch 56 NC 9 Ch 9 COM 158...

Page 29: ...Energizing a relay connects the NO terminal to the COM terminal The module uses reed relays Ruthenium sputtered type that offer very long life with good low level switching performance and excellent...

Page 30: ...39 Ch 24 COM 163 Ch 25 NO 138 Ch 26 NO 63 Ch 27 NO 38 Ch 28 NO 164 Ch 25 COM 137 Ch 26 COM 64 Ch 27 COM 37 Ch 28 COM 165 Ch 29 NO 136 Ch 30 NO 65 Ch 31 NO 36 Ch 32 NO 166 Ch 29 COM 135 Ch 30 COM 66 C...

Page 31: ...NO 71 Ch 5 COM 154 Ch 18 COM 141 Ch 31 COM 66 Ch 43 COM 72 Ch 6 NO 148 Ch 19 NO 59 Ch 32 NO 36 Ch 44 NO 30 Ch 6 COM 147 Ch 19 COM 60 Ch 32 COM 35 Ch 44 COM 29 Ch 7 NO 53 Ch 20 NO 42 Ch 33 NO 167 Ch 45...

Page 32: ...Energizing a relay connects the NO terminal to the COM terminal The modules use reed relays Ruthenium sputtered type that offer very long life with good low level switching performance and excellent...

Page 33: ...NO 172 Ch 41 COM 129 Ch 42 COM 72 Ch 43 COM 29 Ch 44 COM 173 Ch 45 NO 128 Ch 46 NO 73 Ch 47 NO 28 Ch 48 NO 174 Ch 45 COM 127 Ch 46 COM 74 Ch 47 COM 27 Ch 48 COM 175 Ch 49 NO 126 Ch 50 NO 75 Ch 51 NO...

Page 34: ...COM 56 Ch 36 COM 33 Ch 61 COM 182 Ch 86 COM 107 Ch 12 NO 46 Ch 37 NO 169 Ch 62 NO 120 Ch 87 NO 93 Ch 12 COM 45 Ch 37 COM 170 Ch 62 COM 119 Ch 87 COM 94 Ch 13 NO 157 Ch 38 NO 132 Ch 63 NO 81 Ch 88 NO...

Page 35: ...f relay module is intended for switching heavy AC or DC loads or for slaving up large external relays and solenoids It uses armature power relays gold flash over silver alloy The module has two 20 pin...

Page 36: ...ectors And System Connections The following graphs represent the voltage current derating and relay life expectancy Figure 6 M9135A Front Panel Connector viewed from the front panel Pinout Figure 7 M9...

Page 37: ...Block 78 pin shielded female D Sub Y1187A Connector Cable 78 pin male to female 1 Meter Y1188A Connector Cable 78 pin male to female 2 Meter M9131A M9132A and M9133A Accessories Model Description Y11...

Page 38: ...relief The recommended torque for the screw terminal is 0 12 0 15 Nm PTFE insulated cables are recommended The following diagram shows the pinout of the connector block The pin numbers match the pin n...

Page 39: ...ain relief The recommended torque for the screw terminal is 0 12 0 15 Nm PTFE insulated cables are recommended The following diagram shows the pinout of the connector block The pin numbers match the p...

Page 40: ...the Keysight M9131A M9132A and M9133A PXI switch modules with the 200 pin D Type connector It is built from four bundles of 50 wire 28AWG ribbon cable A braided sleeve covers each of the four bundles...

Page 41: ...highest voltage applied to any single channel Figure 12 Y1189A Y1190A 50 pin connectors pinouts 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 1 18 2 19 3 4 5 20 21 22 6 23 7 24 8 25 9 26 10 27 1...

Page 42: ...ble assemblies are required for the M9135A module Notes on unterminated end White wires are odd pin numbers 01 03 05 17 19 Orange wires are even pin numbers 02 04 06 18 20 Colored beads indicate the p...

Page 43: ...the M9135A module Figure 15 Connector diagram on left viewed from the solder cup contact side not the front of the connector A X Connector Pin Unterminated Wire Number Color Code Wire Color Connector...

Page 44: ...to the assembly Be careful to note the polarity and how they will match the screw lock nuts on the module connector 4 Insert the roll pins into the screw lock thumbscrews to secure them to the screw l...

Page 45: ...and lift up on the strain relief bar Refer to Figure 18 4 Insert your cable under the strain relief bar and retighten the two strain relief screws 5 To reassemble the clamshell make certain the screw...

Page 46: ...bstantially more current or power than a module can handle It is important to provide external current limiting such as fuses if the module inputs are connected to high energy sources For the latest s...

Page 47: ...are restored before turning on power to the equipment These modules are not for connection to Mains Pollution Degree 1 No pollution or only dry non conductive pollution occurs The pollution has no inf...

Page 48: ...47 Keysight PXI General Purpose Switch Modules Startup Guide Environmental Operating Conditions...

Page 49: ...Keysight M9195A PXIe Digital Stimulus Response Startup Guide 1...

Page 50: ...This information is subject to change without notice Keysight Technologies 2014 2018 Edition 5 December 2018 M9130 90001 M9130 90001 www keysight com...

Reviews: