background image

33

Keysight PXI General Purpose Switch Modules Startup Guide

Module Front Panel Connectors And System Connections

Table 4

M9133A Channel Number to Connector Pinout

Channel

Pin 

No.

Channel

Pin 

No.

Channel

Pin 

No.

Channel

Pin 

No.

Ch 1 NO

151

Ch 26 NO

138

Ch 51 NO

75

Ch 76 NO

14

Ch 1 COM

152

Ch 26 COM

137

Ch 51 COM

76

Ch 76 COM

13

Ch 2 NO

150

Ch 27 NO

63

Ch 52 NO

26

Ch 77 NO

189

Ch 2 COM

149

Ch 27 COM

64

Ch 52 COM

25

Ch 77 COM

190

Ch 3 NO

51

Ch 28 NO

38

Ch 53 NO

177

Ch 78 NO

112

Ch 3 COM

52

Ch 28 COM

37

Ch 53 COM

178

Ch 78 COM

111

Ch 4 NO

50

Ch 29 NO

165

Ch 54 NO

124

Ch 79 NO

89

Ch 4 COM

49

Ch 29 COM

166

Ch 54 COM

123

Ch 79 COM

90

Ch 5 NO

153

Ch 30 NO

136

Ch 55 NO

77

Ch 80 NO

12

Ch 5 COM

154

Ch 30 COM

135

Ch 55 COM

78

Ch 80 COM

11

Ch 6 NO

148

Ch 31 NO

65

Ch 56 NO

24

Ch 81 NO

191

Ch 6 COM

147

Ch 31 COM

66

Ch 56 COM

23

Ch 81 COM

192

Ch 7 NO

53

Ch 32 NO

36

Ch 57 NO

179

Ch 82 NO

110

Ch 7 COM

54

Ch 32 COM

35

Ch 57 COM

180

Ch 82 COM

109

Ch 8 NO

48

Ch 33 NO

167

Ch 58 NO

122

Ch 83 NO

91

Ch 8 COM

47

Ch 33 COM

168

Ch 58 COM

121

Ch 83 COM

92

Ch 9 NO

155

Ch 34 NO

134

Ch 59 NO

79

Ch 84 NO

10

Ch 9 COM

156

Ch 34 COM

133

Ch 59 COM

80

Ch 84 COM

9

Ch 10 NO

146

Ch 35 NO

67

Ch 60 NO

22

Ch 85 NO

193

Ch 10 COM

145

Ch 35 COM

68

Ch 60 COM

21

Ch 85 COM

194

Ch 11 NO

55

Ch 36 NO

34

Ch 61 NO

181

Ch 86 NO

108

Ch 11 COM

56

Ch 36 COM

33

Ch 61 COM

182

Ch 86 COM

107

Ch 12 NO

46

Ch 37 NO

169

Ch 62 NO

120

Ch 87 NO

93

Ch 12 COM

45

Ch 37 COM

170

Ch 62 COM

119

Ch 87 COM

94

Ch 13 NO

157

Ch 38 NO

132

Ch 63 NO

81

Ch 88 NO

8

Ch 13 COM

158

Ch 38 COM

131

Ch 63 COM

82

Ch 88 COM

7

Ch 14 NO

144

Ch 39 NO

69

Ch 64 NO

20

Ch 89 NO

195

Ch 14 COM

143

Ch 39 COM

70

Ch 64 COM

19

Ch 89 COM

196

Ch 15 NO

57

Ch 40 NO

32

Ch 65 NO

183

Ch 90 NO

106

Ch 15 COM

58

Ch 40 COM

31

Ch 65 COM

184

Ch 90 COM

105

Ch 16 NO

44

Ch 41 NO

171

Ch 66 NO

118

Ch 91 NO

95

Ch 16 COM

43

Ch 41 COM

172

Ch 66 COM

117

Ch 91 COM

96

Ch 17 NO

159

Ch 42 NO

130

Ch 67 NO

83

Ch 92 NO

6

Ch 17 COM

160

Ch 42 COM

129

Ch 67 COM

84

Ch 92 COM

5

Ch 18 NO

142

Ch 43 NO

71

Ch 68 NO

18

Ch 93 NO

197

Ch 18 COM

141

Ch 43 COM

72

Ch 68 COM

17

Ch 93 COM

198

Ch 19 NO

59

Ch 44 NO

30

Ch 69 NO

185

Ch 94 NO

104

Ch 19 COM

60

Ch 44 COM

29

Ch 69 COM

186

Ch 94 COM

103

Ch 20 NO

42

Ch 45 NO

173

Ch 70 NO

116

Ch 95 NO

97

Ch 20 COM

41

Ch 45 COM

174

Ch 70 COM

115

Ch 95 COM

98

Ch 21 NO

161

Ch 46 NO

128

Ch 71 NO

85

Ch 96 NO

4

Ch 21 COM

162

Ch 46 COM

127

Ch 71 COM

86

Ch 96 COM

3

Ch 22 NO

140

Ch 47 NO

73

Ch 72 NO

16

Ch 97 NO

199

Ch 22 COM

139

Ch 47 COM

74

Ch 72 COM

15

Ch 97 COM

200

Ch 23 NO

61

Ch 48 NO

28

Ch 73 NO

187

Ch 98 NO

102

Ch 23 COM

62

Ch 48 COM

27

Ch 73 COM

188

Ch 98 COM

101

Ch 24 NO

40

Ch 49 NO

175

Ch 74 NO

114

Ch 99 NO

99

Ch 24 COM

39

Ch 49 COM

176

Ch 74 COM

113

Ch 99 COM

100

Ch 25 NO

163

Ch 50 NO

126

Ch 75 NO

87

Ch 100 NO

1

Ch 25 COM

164

Ch 50 COM

125

Ch 75 COM

88

Ch 100 

COM

2

Summary of Contents for M9130A

Page 1: ...Keysight PXI General Purpose Switch Modules M9130A M9131A M9132A M9133A M9135A Startup Guide...

Page 2: ......

Page 3: ...T NOTICE IN FUTURE EDI TIONS FURTHER TO THE MAXIMUM EXTENT PERMITTED BY APPLICABLE LAW KEYSIGHT DISCLAIMS ALL WAR RANTIES EITHER EXPRESS OR IMPLIED WITH REGARD TO THIS MANUAL AND ANY INFORMATION CONTA...

Page 4: ...rform proce dures involving cover or shield removal unless you are qualified to do so DO NOT operate damaged equipment Whenever it is possible that the safety protection features built into this prod...

Page 5: ...ltage or have additional insulation added rated for the maximum voltage and will be isolated from conductive parts using a thermal compound or tape rated for the maximum voltage applied Do not mount m...

Page 6: ...Aus tralia EMC Framework regulations under the terms of the Radio Commu nication Act of 1992 ICES NMB 001 indicates that this ISM device complies with the Canadian ICES 001 This symbol represents the...

Page 7: ...Keysight IO Libraries Connection Expert 18 Verify operation 19 Characteristics 19 Default Path Settings 20 Module Functional Description 20 Module Programming 21 Identifying Channel Numbers 22 Module...

Page 8: ...vii Keysight PXI General Purpose Switch Modules Startup Guide High Energy Sources 45 Environmental Operating Conditions 46...

Page 9: ...es M9130A PXI SPDT Switch 26 channels Armature Relays M9131A PXI SPDT Switch 64 channels Reed Relays M9132A PXI SPST Switch 50 channels Reed Relays M9133A PXI SPST Switch 100 channels Reed Relays M913...

Page 10: ...onic assemblies should be performed at a static safe work station The following figure shows an example of a static safe work station using two types of ESD protection Purchase acceptable ESD accessor...

Page 11: ...to the Support information on the product web page at www keysight com find pxiswitch 3 Write the following information on a tag and attach it to the malfunctioning equipment Name and address of owner...

Page 12: ...ct printed documentation in PDF format for the PXI General Purpose switch modules An Automation Ready CD with Keysight IO Libraries Suite version 16 0 or later Any other accessories that you ordered c...

Page 13: ...eater recommended 1 GB minimum 1 GB minimum Available hard disk space 1 5 GB available hard disk space includes 1GB available for Microsoft NET Framework 3 5 SP1 100MB for Keysight IO Libraries Suite...

Page 14: ...onnection Expert the IVI Shared Components and the VISA Shared Components 1 Insert the Automation Ready CD with Keysight IO Libraries Suite into the CD ROM drive of your system controller Wait a few s...

Page 15: ...modules using Microsoft development environments e g Visual Studio C C C Visual Basic Keysight VEE MATLAB or National Instruments LabVIEW Accept the license terms and click Next Keysight Software Lice...

Page 16: ...he laptop With a Keysight Y1200A cable connect the adapter to the System Interface module on the PXI chassis Using an embedded computer Refer to the figure above If you are using an embedded controlle...

Page 17: ...lot by placing the module card edges into the front module guides top and bottom Slide the module to the rear of the chassis Ensure that the injector ejector handle is pushed down in the unlatched dow...

Page 18: ...nt desktop or laptop PC power on the computer Choose the default option for any Found New Hardware dialogs Chassis Power Down Process If you are using a remote controller linked to the M9021A Cable In...

Page 19: ...iguration In the Windows Notification Area click the IO icon then click Keysight Connection Expert Locate your interfaces and instruments in the Keysight Connection Expert Explorer Pane The following...

Page 20: ...e SFP enters it s monitor mode In this mode you cannot change relay state and the menu buttons are grayed out However as the other application controls the channels the SFP interface monitors and disp...

Page 21: ...odules use this supply 5Vdc 12Vdc ground as well as the control signals from the chassis backplane The relay drivers are activated by the PCI Bridge U1 via output registers There are no user serviceab...

Page 22: ...Many methods in the IviSwtch interfaces accept a channel string parameter The channel names supported by the AgMSwitch driver depend upon the specific switch module to which the driver is connected In...

Page 23: ...where chn is the actual channel number For example RouteCloseChannel ch8 will close the relay that connects channel 8 COM common to it s NO Normally Open terminal The following graphic shows the Soft...

Page 24: ...between the COM and NO terminals The module is a general purpose armature relay module They are suitable for use where reed relay based switching modules do not have sufficient voltage or current carr...

Page 25: ...6 COM 48 Ch 13 COM 78 Ch 20 COM 30 Ch 26 COM 39 CH 6 NO 67 CH 13 NO 58 CH 20 NO 10 CH 26 NO 19 Ch 6 NC 68 Ch 13 NC 59 Ch 20 NC 11 Ch 26 NC 20 Ch 7 COM 69 Ch 14 COM 21 CH 7 NO 49 CH 14 NO 1 All pins a...

Page 26: ...al Energizing a relay disconnects the NC terminal and creates a signal path between the COM and NO terminals The modules uses reed relays Ruthenium sputtered type that offer very long life with good l...

Page 27: ...NC 130 Ch 26 NC 71 Ch 27 NC 30 Ch 28 NC 172 Ch 29 NO 129 Ch 30 NO 72 Ch 31 NO 29 Ch 32 NO 173 Ch 29 COM 128 Ch 30 COM 73 Ch 31 COM 28 Ch 32 COM 174 Ch 29 NC 127 Ch 30 NC 74 Ch 31 NC 27 Ch 32 NC 175 C...

Page 28: ...NC 56 Ch 23 NC 68 Ch 39 NC 80 Ch 55 NC 92 Ch 8 COM 46 Ch 24 COM 34 Ch 40 COM 22 Ch 56 COM 10 Ch 8 NO 47 Ch 24 NO 35 Ch 40 NO 23 Ch 56 NO 11 Ch 8 NC 45 Ch 24 NC 33 Ch 40 NC 21 Ch 56 NC 9 Ch 9 COM 158...

Page 29: ...Energizing a relay connects the NO terminal to the COM terminal The module uses reed relays Ruthenium sputtered type that offer very long life with good low level switching performance and excellent...

Page 30: ...39 Ch 24 COM 163 Ch 25 NO 138 Ch 26 NO 63 Ch 27 NO 38 Ch 28 NO 164 Ch 25 COM 137 Ch 26 COM 64 Ch 27 COM 37 Ch 28 COM 165 Ch 29 NO 136 Ch 30 NO 65 Ch 31 NO 36 Ch 32 NO 166 Ch 29 COM 135 Ch 30 COM 66 C...

Page 31: ...NO 71 Ch 5 COM 154 Ch 18 COM 141 Ch 31 COM 66 Ch 43 COM 72 Ch 6 NO 148 Ch 19 NO 59 Ch 32 NO 36 Ch 44 NO 30 Ch 6 COM 147 Ch 19 COM 60 Ch 32 COM 35 Ch 44 COM 29 Ch 7 NO 53 Ch 20 NO 42 Ch 33 NO 167 Ch 45...

Page 32: ...Energizing a relay connects the NO terminal to the COM terminal The modules use reed relays Ruthenium sputtered type that offer very long life with good low level switching performance and excellent...

Page 33: ...NO 172 Ch 41 COM 129 Ch 42 COM 72 Ch 43 COM 29 Ch 44 COM 173 Ch 45 NO 128 Ch 46 NO 73 Ch 47 NO 28 Ch 48 NO 174 Ch 45 COM 127 Ch 46 COM 74 Ch 47 COM 27 Ch 48 COM 175 Ch 49 NO 126 Ch 50 NO 75 Ch 51 NO...

Page 34: ...COM 56 Ch 36 COM 33 Ch 61 COM 182 Ch 86 COM 107 Ch 12 NO 46 Ch 37 NO 169 Ch 62 NO 120 Ch 87 NO 93 Ch 12 COM 45 Ch 37 COM 170 Ch 62 COM 119 Ch 87 COM 94 Ch 13 NO 157 Ch 38 NO 132 Ch 63 NO 81 Ch 88 NO...

Page 35: ...f relay module is intended for switching heavy AC or DC loads or for slaving up large external relays and solenoids It uses armature power relays gold flash over silver alloy The module has two 20 pin...

Page 36: ...ectors And System Connections The following graphs represent the voltage current derating and relay life expectancy Figure 6 M9135A Front Panel Connector viewed from the front panel Pinout Figure 7 M9...

Page 37: ...Block 78 pin shielded female D Sub Y1187A Connector Cable 78 pin male to female 1 Meter Y1188A Connector Cable 78 pin male to female 2 Meter M9131A M9132A and M9133A Accessories Model Description Y11...

Page 38: ...relief The recommended torque for the screw terminal is 0 12 0 15 Nm PTFE insulated cables are recommended The following diagram shows the pinout of the connector block The pin numbers match the pin n...

Page 39: ...ain relief The recommended torque for the screw terminal is 0 12 0 15 Nm PTFE insulated cables are recommended The following diagram shows the pinout of the connector block The pin numbers match the p...

Page 40: ...the Keysight M9131A M9132A and M9133A PXI switch modules with the 200 pin D Type connector It is built from four bundles of 50 wire 28AWG ribbon cable A braided sleeve covers each of the four bundles...

Page 41: ...highest voltage applied to any single channel Figure 12 Y1189A Y1190A 50 pin connectors pinouts 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 1 18 2 19 3 4 5 20 21 22 6 23 7 24 8 25 9 26 10 27 1...

Page 42: ...ble assemblies are required for the M9135A module Notes on unterminated end White wires are odd pin numbers 01 03 05 17 19 Orange wires are even pin numbers 02 04 06 18 20 Colored beads indicate the p...

Page 43: ...the M9135A module Figure 15 Connector diagram on left viewed from the solder cup contact side not the front of the connector A X Connector Pin Unterminated Wire Number Color Code Wire Color Connector...

Page 44: ...to the assembly Be careful to note the polarity and how they will match the screw lock nuts on the module connector 4 Insert the roll pins into the screw lock thumbscrews to secure them to the screw l...

Page 45: ...and lift up on the strain relief bar Refer to Figure 18 4 Insert your cable under the strain relief bar and retighten the two strain relief screws 5 To reassemble the clamshell make certain the screw...

Page 46: ...bstantially more current or power than a module can handle It is important to provide external current limiting such as fuses if the module inputs are connected to high energy sources For the latest s...

Page 47: ...are restored before turning on power to the equipment These modules are not for connection to Mains Pollution Degree 1 No pollution or only dry non conductive pollution occurs The pollution has no inf...

Page 48: ...47 Keysight PXI General Purpose Switch Modules Startup Guide Environmental Operating Conditions...