86 Language Dictionary
Command Summary
Command
Parameters
Subsystem Commands
ABOR
(none)
CAL
(See Appendix A in the Operating Manual)
[SOUR]:CURR[:LEV][:IMM][:AMPL]
<NRf+>[suffix]
[SOUR]:CURR[:LEV][:IMM][:AMPL]?
(none) |MIN|MAX
[SOUR]:CURR[:LEV]:TRIG[:AMPL]
<NRf+>[suffix]
[SOUR]:CURR[:LEV]:TRIG[:AMPL]?
(none) |MIN|MAX
[SOUR]:CURR:PROT:STAT
0 |l | ON|OFF
(SOUR]:CURR:PROT:STAT?
(none)
[SOUR]:DIG:DATA[:VAL]
<NRf>
[SOUR]:DIG:DATA[:VAL]?
(none)
DISP[WIND]:MODE
NORM|TEXT
DISP(WIND]:MODE?
(none)
DISP[:WIND][:STAT]
0 |l |
OFF|ON
DISP[:WIND][:STAT]?
(none)
DISP[:WIND]:TEXT[:DATA]
<STR>
DISP[:WIND]:TEXT[:DATA]?
(none)
INIT[:IMM)
(none)
INIT:CONT
0 | l |
OFF|ON
INIT:CONT?
(none)
Common Commands
Command
Parameters
Command
Parameters
Command
Parameters
*CLS
(None)
*OPC?
(None)
*SRE
<NRf>
*ESE
<NRf>
*PSC
<bool>
*SRE?
(None)
*ESE?
(None)
*PSC?
(None)
*STB?
(None)
*ESR?
(None)
*RCL
<NRf>
*TRG
(None)
*IDN?
(None)
*RST
(None)
*TST?
(None)
*OPC
(None)
*SAV
<NRf>
*WAI
(None)
Programming Parameters
Table 7-1 list the programming parameters. For programming accuracy and resolution, refer to Appendix A.
Table 7-1. Power supply Programming Parameters (see note)
Parameter
CURR[:LEV] MAX
and
CURR[:LEV]:TRIG MAX
30.71 A
(Programming range
is
0
to
MAX)
*RST
Current Value
0.14 A
OUTP:PROT:DEL
*RST Value
0 to 32.727 s (MAX)
200 ms
VOLT[:LEV] MAX
and
VOLT[:LEV]:TRIG MAX
81.9 V
(Programming range is 0 to
MAX)
*RST
Voltage Value
0 V
VOLT:PROT MAX
96.0 V
(Programming range is 0 to
MAX)
*RST
OVP value
MAX