Keysight E1418A Service Guide
Keysight E1418A Specifications
Power Requirements
Cooling Requirements
For a 10 °C rise
Current Required (Amps)
Configuration
+5 V DC
+5 V
Dynamic
+12 V DC
+12 V
Dynamic
+24 V DC
+24 V
Dynamic
–24 V DC
–24 V
Dynamic
8 Channel
Non-Isolated
0.70
0.01
0.04
0.01
0.44
0.01
0.44
0.01
8 Channel
Isolated
0.75
0.01
0.04
0.01
0.88
0.01
0.00
0.00
16 Channel
Non-Isolated
1.25
0.01
0.04
0.01
0.88
0.01
0.88
0.01
16 Channel
Isolated
1.40
0.01
0.04
0.01
1.60
0.01
0.00
0.00
Air Flow
∆ P
Avg Watts/slot
8 Channel configurations
2.0 liters/second
0.10 mm H2O
25.4
16 Channel configurations
3.9 liters/second
0.18 mm H2O
49.0