Measurement Accessories

The following table lists the currently available accessories that may be used with 
Keysights millimeter wave network analyzer solutions. These accessories are not 
supplied with the N5290A or N5291A and can be purchased separately.

Accessory Type

Model Number  Description

Calibration kit

85059B

DC to 120 GHz 1.0mm Calibration kit

Verification kit

85059V

1.0 mm Verification kit

Power sensors

U8489A

DC to 120 GHz 1.0 mm USB power sensor

1

V8486A

50 to 75 GHz Waveguide power sensor

Test port cables

11500JK10

110 GHz, 1.0 mm (m-f) Test port cable (10 cm)

3

11500I

110 GHz, 1.0 mm (f-f) Test port cable (8.8 cm)

3

11500J

110 GHz, 1.0 mm (m-f) Test port cable (16 cm)

3

11500K

110 GHz, 1.0 mm (m-f) Test port cable (20 cm)

3

11500K

110 GHz, 1.0 mm (m-f) Test port cable (24 cm)

3

Waveguide adapters

V281C

1.0 mm (f) to V-band waveguide adapter

V281D

1.0 mm (m) to V-band waveguide adapter

W281C

1.0 mm (f) to V-band waveguide adapter

W281D

1.0 mm (m) to V-band waveguide adapter

1.0 mm Coaxial adapters

11920A

110 GHz, 1.0 mm (m) to 1.0 mm (m) adapter

11920B

110 GHz, 1.0 mm (f) to 1.0 mm (f) adapter

11920C

110 GHz, 1.0 mm (m) to 1.0 mm (f) adapter

Y1900B

120 GHz , 1.0 mm (f) to 1.0 mm (f) Ruggedized adapter

Y1900C

120 GHz , 1.0 mm (m) to 1.0 mm (f) Ruggedized adapter

Y1910A

120 GHz , 1.0 mm (m) to 1.0 mm (m) Standard adapter

Y1910B

120 GHz , 1.0 mm (f) to 1.0 mm (f) Standard adapter

Y1910C

120 GHz , 1.0 mm (m) to 1.0 mm (f) Standard adapter

1.85 mm Coaxial adapters

11921E

1.0 mm (m) to 1.85 mm (m) adapter

11921F

1.0 mm (f) to 1.85 mm (f) adapter

11921G

1.0 mm (m) to 1.85 mm (f) adapter

11921H

1.0 mm (f) to 1.85 mm (m) adapter

2.4 mm Coaxial adapters

11922A

1.0 mm (m) to 2.4 mm (m) adapter

11922B

1.0 mm (f) to 2.4 mm (f) adapter

11922C

1.0 mm (m) to 2.4 mm (f) adapter

11922D

1.0 mm (f) to 2.4 mm (m) adapter

Package launch

11923A

1.0 mm (f) Microcircuit connector launch assembly

1.  Recommended for use with N5290/91A millimeter wave network analyzer solution.
2.  The 11500IKxx cable is recommended for use with the probe positioners on the Cascade probe station.
3.  These cables will operate to 120 GHz mode free even though they are specified to work to 110 GHz.

Цены и срок поставки уточняйте на сайте

 

www.2test.ru

, по телефону:

 

+ 7 495 215-57-17

 

или

 

[email protected]

Summary of Contents for N5290A

Page 1: ...Keysight Technologies Millimeter Wave Network Analyzers N5290A N5291A Configuration Guide Цены и срок поставки уточняйте на сайте www 2test ru по телефону 7 495 215 57 17 или info 2test ru ...

Page 2: ...nfigurations 11 Step 2 N5292A Millimeter wave test controllers 12 Step 3 N5293 5A Millimeter wave frequency extenders 12 Configuring OML and VDI Banded Frequency Extenders with N5290 91A 13 Supported Software Application Options 13 Measurement Applications 14 On Wafer Measurements 14 Material Measurements 14 N1500A materials measurement suit 14 Antenna Measurements Solutions 14 Measurement Accesso...

Page 3: ...cessories In addition it will provide configuration information for creating a broadband solution using separate system components The N5290A and N5291A millimeter wave vector network analyzer is a network analyzer solution that utilizes both the PNA and PNA X platforms as the measurement engine Introduction N5290A 4 Port Millimeter Wave Network Analyzer 900 Hz 500 Hz to 110 GHz N5291A 4 Port Mill...

Page 4: ... pre and post adjustment data with measurement uncertainty information compliant to the ANSI NCSL Z540 standard Documentation The PNA Series instruments are equipped with an Online Help system available within the instrument in English only All PNA documentation is available on the web www keysight com find pna Calibration Software Licenses Built in performance test software for standard compliant...

Page 5: ...67 GHz 4 port with Options 425 029 PNA PNA X Frequency coverage Bias tee configuration Cable length N5293AX03 900 Hz to 110 GHz Low frequency bias combiner with built in 50V 1A bias tee 1 2 m cable option N5295AX03 900 Hz to 120 GHz Low frequency bias combiner with built in 50V 1A bias tee 1 2 m cable option PNA PNA X Models N5292A Test options Interconnect cable options 2 Port test set controller...

Page 6: ...29 N5292A Test set Option 400 and 442 Quantity 4 of N5293AX03 110 GHz Frequency extenders Option 403 N5247B PNA X Option 020 425 029 N5292A Test set with Option 400 and 444 Quantity 4 N5293AX03 110 GHz Frequency extenders Note For details or to add other PNA or PNA X options to the above listed minimum configuration please refer to the PNA Family Configuration Guide literature number 5992 1465EN K...

Page 7: ...0 029 425 N5292A Test set Option 400 and 442 Quantity 4 of N5295AX03 120 GHz Frequency extenders Option 403 N5247B PNA X Option 020 029 425 N5292A Test set with Option 400 and 444 Quantity 4 N5295AX03 120 GHz Frequency extenders Note For details or to add other PNA or PNA X options to the above listed minimum configuration please refer to the PNA Family Configuration Guide literature number 5992 1...

Page 8: ...on Guide System block diagrams N5290 91A Option 201 System level block diagram N5222B with Option 205 N5290 91A Option 202 System level block diagram N5227B with Option 205 Цены и срок поставки уточняйте на сайте www 2test ru по телефону 7 495 215 57 17 или info 2test ru ...

Page 9: ...e System block diagrams continued N5290 91A Option 401 System level block diagram N5242B with Option 425 N5290 91A Option 402 System level block diagram N5242B with Option 425 029 Цены и срок поставки уточняйте на сайте www 2test ru по телефону 7 495 215 57 17 или info 2test ru ...

Page 10: ...zers N5290A N5291A Cofiguration Guide System block diagrams continued N5290 91A Option 403 System level block diagram N5247B with Option 425 029 Цены и срок поставки уточняйте на сайте www 2test ru по телефону 7 495 215 57 17 или info 2test ru ...

Page 11: ...els listed require Option 020 3 Option 205 allows the millimeter wave system to have a start frequency of 900 Hz Product option1 2 Description Low frequency extension N5242B 201 26 5 GHz 2 Port PNA X with configurable test set option n a N5242B 401 26 5 GHz 4 Port PNA X with configurable test set option Option 4253 N5244B 201 43 5 GHz 2 Port PNA X with configurable test set option n a N5244B 401 4...

Page 12: ...4B N5225B N5244B N5245B N5227B N5247B Option 224 Interconnect kit for 2 port test set and 2 port VNA with 2 4 mm ports Option 424 Interconnect kit for 4 port test set and 2 port VNA with 2 4 mm ports 4 Port PNA PNA X N5222B N5242B Option 242 Interconnect kit for 2 port test set and 4 port VNA with 3 5 mm ports Option 442 Interconnect kit for 4 port test set and 4 port VNA with 3 5 mm ports N5224B ...

Page 13: ...r supply VDI mini frequency extenders N5290A304 Includes DC power supplies with mini frequency extenders Supported Software Application Options The following listed software options will operate over the full range of the pre configured N5290 91A systems Software product Description N5290 91 Start frequency support 900 Hz 10 MHz S93007A Automatic fixture removal Yes Yes S93010A Time domain analysi...

Page 14: ...tion 3 A set of V or W band horn antennas 4 Thomas Keating quasi optical positioner or a Swiss to 12 corrugated waveguide fixture N1500A materials measurement suite The N1500A 001 UL8 materials measurement suite calculates the permittivity and permeability of material samples placed in a coaxial airline or a rectangular waveguide The measurement technique works well for solid materials that can be...

Page 15: ...aveguide adapter 1 0 mm Coaxial adapters 11920A 110 GHz 1 0 mm m to 1 0 mm m adapter 11920B 110 GHz 1 0 mm f to 1 0 mm f adapter 11920C 110 GHz 1 0 mm m to 1 0 mm f adapter Y1900B 120 GHz 1 0 mm f to 1 0 mm f Ruggedized adapter Y1900C 120 GHz 1 0 mm m to 1 0 mm f Ruggedized adapter Y1910A 120 GHz 1 0 mm m to 1 0 mm m Standard adapter Y1910B 120 GHz 1 0 mm f to 1 0 mm f Standard adapter Y1910C 120 ...

Page 16: ...0044 1 0 mm m m adapter 85059 60045 1 0 mm f f adapter 85059 60046 1 0 mm m f adapter 85059B Torque wrench Part number Description Part number Description 8710 2812 6 mm 4 in lb torque wrench 8710 2156 14 mm 4 in lb torque wrench 8710 2813 6 mm open end wrench 85059B DC to 120 GHz 1 0 mm Calibration kit The 85059B calibration kit includes the following items 85059V 1 0 mm Verification kits 85059V ...

Page 17: ...0 60006 1 2 m length The different components may be purchased as replaceable parts see part numbers in parenthesis A single N5290A301 adapter is required per N5293A frequency extender used in the system Frequency extender desktop positioner N5290A302 1 2 Designed to position the N5293A and N5295A frequency extenders when the system is used on a desktop and provides the following capability Easily...

Page 18: ...058B calibration kit It is a recommended accessory when the an 85059B calibration kit is not purchased with the system Cable adapter for OML VDI frequency extenders N5290A304 This accessory is required if there is a need to connect an OML or VDI module to the N5292A test set controller and use the configured millimeter wave system to control the OML VDI frequency extenders The adapter assembly wil...

Reviews: