  1. Graph display status ON or OFF. Only on 2-channel models. [n] is for channel n.
  2. Y-axis data type I (A), V (V), R (

W

), P (W), or MATH

  3. Y-axis scale LINEAR or LOG
  4. X-axis data type I (A), V (V), R (

W

), P (W), MATH, t (s), V1, or V2

  5. X-axis scale LINEAR or LOG
  6. Graph maximum value
  7. Graph minimum value
  8. Channel 1 and/or 2 source output value, limit value, or none (controlled by the Ch n Source, Ch n Limit, or Hide 
      Ch n assist key)
  9. Channel 1 and/or 2 Y-axis data at the active X-cursor position. ----.---- is displayed for the no-data position.
10. Cursor data (controlled by the Show Cursors or Hide Cursors assist key)

      First line         Positions and distance (e.g. I1, I2, ΔA) of Y-cursors 1 and 2
      Second line    Positions and distance (e.g. t1, t2, Δt) of X-cursors 1 and 2

1

2

3

4

5

6

7

8

9

10

Graph View

  1. Displays status ON or OFF, on B2911B
      Displays status Ch 1, Ch 2, or OFF, on B2912B
      Two lines can be displayed on the graph. [1] indicates the graph setup for line 1. [2] indicates the graph setup 
      for line 2.
  2. Y-axis data type I, V, R, or P.
  3. Y-axis scale per division A/div., V/div., 

W

/div., or W/div.

  4. X-axis scale per division s/div.
  5. X-axis minimum value (minimum timestamp)
  6. Y-axis offset values for line 1 and 2
  7. X-axis maximum value (maximum timestamp)
  8. See Graph View.
  9. See Graph View.
10. See Graph View.

Roll View

1 2

3

4

5

6

7

8

9

10

Displays the time domain graph 
for plotting the channel 1 and/or 
2 measurement data.
(Only on B2911B/B2912B) 

Displays the graph for plotting 
the channel 1 and/or 2 
measurement or math result.

Summary of Contents for B2900B Series

Page 1: ...ite To connect the device under test DUT optional 1 B2900 terminals use banana jacks Prepare test leads that use banana plugs 2 Connect the test leads as shown in the figures For using 4 wire connecti...

Page 2: ...urns the channel off if it is in the output status even if it is in the remote status Two switches on 2 channel models The switch turns green if the channel is enabled The switch turns red if the chan...

Page 3: ...e Ch2 B2902B Graph G Single 1 Roll B2911B Trigger auto Trigger active High voltage Floating Remote Local lockout Error MOVE EDIT LXI LAN status indicator View mode 1 2 3 4 MOVE status EDIT status 1 Pr...

Page 4: ...ly Performing Measurement Disabling the Channel Press the Ch1 switch to disable channel 1 This turns off the switch light Measured value a Press the View key to display the Single view Press to start...

Page 5: ...and the status changes to MOVE blue e Use the rotary knob arrow keys or numeric alpha keys to set the Start sweep start Stop sweep stop and Step sweep step or Points number of sweep steps values 4 Pr...

Page 6: ...t result Pass or Fail Single View Range Setup Sweep Setup Pulse Setup Trigger Setup Source Volts Spot Measure Amps Source Amps Spot Measure Volts Measure Ohms Constant voltage output range Current mea...

Page 7: ...cursors 1 and 2 Second line Positions and distance e g t1 t2 t of X cursors 1 and 2 1 2 3 4 5 6 7 8 9 10 Graph View 1 Displays status ON or OFF on B2911B Displays status Ch 1 Ch 2 or OFF on B2912B Tw...

Page 8: ...surement error caused by the residual resistance of the test leads or cables Grounded and Floating Measurements With the default setting Low Force terminal is connected to the chassis ground However i...

Reviews: