Inspect for damage

Step 1: Unpack and Inspect the Module

The module is shipped in materials which prevent damage from static. The module should only be

removed from the packaging in an anti-static area ensuring that correct anti-static precautions are
taken. Store all modules in anti-static envelopes when not in use.

ESD Precautions

Electrostatic discharge (ESD) can damage or destroy
electronic components. Use a static-safe work station to
perform all work on electronic assemblies. The figure (left)
shows a static-safe work station using two types of ESD
protection: conductive table-mat and wrist-strap
combination, and conductive floor-mat and heel-strap
combination. Both types, when used together, provide a
significant level of ESD protection. Of the two, only the
table-mat and wrist-strap combination provides adequate
ESD protection when used alone. To ensure user safety, the
static-safe accessories must provide at least 1 MΩ of
isolation from ground.

Figure 1 - A typical ESD workstation

Inspect for damage

After unpacking the module, carefully inspect it for any shipping damage. Report any damage to the shipping agent
immediately, as such damage is not covered by the warranty. Warranty information for your product can be found
at:

www.agilent.com/find/warranty

.

Information on preventing damage to your Agilent equipment can be found at

www.agilent.com/find/tips

.

To avoid damage when handling a module, do not touch exposed connector pins.

Return the module for service

Should it become necessary to return the M9202A module for repair or service, follow the steps below:

1. Review the warranty information shipped with your product.

2. Contact Agilent for instructions on the return of equipment for repair. If you need assistance finding Agilent

contact information go to

www.agilent.com/find/assist

(worldwide contact information for repair and service)

or refer to the “Support” information on the product web page at

www.agilent.com/find/PXI-Digitizers

.

3. Write the following information on a tag and attach it to the malfunctioning equipment.

l

Name and address of owner. A P.O. box is not acceptable as a return address.

8

M9202A PXI Express 12-bit Wideband IF Digitizer Startup Guide

Summary of Contents for Agilent Technologies PXI Express M9202A

Page 1: ...bit Wideband IF Digitizer M9202A Startup Guide NOTICE This document contains references to Agilent Technologies Agilent s former Test and Measurement business has become Keysight Technologies For more...

Page 2: ...or contract clause Use duplication or disclosure of Software is subject to Agilent Technologies standard commercial license terms and non DOD Departments and Agencies of the U S Government will recei...

Page 3: ...the voltage being measured The instrument and accessories must be used in accordance with its specifications and operating instructions or the safety of the equipment may be impaired Do not exceed th...

Page 4: ...nt means caution risk of danger You should refer to the operating instructions located in the user documen tation in all cases where the symbol is marked on the instrument This symbol indicates the ti...

Page 5: ...anel Connectors 13 Front Panel LED 13 Step 5 Verify Operation of the M9202A Module 14 Conducting a Self Test 15 Conduct M9202A Operational check optional 16 Requirements for Verification 16 Required H...

Page 6: ...Documentation Map 6 M9202A PXI Express 12 bit Wideband IF Digitizer Startup Guide...

Page 7: ...elect Technical Support Manuals l Help system for the Soft Front Panel l Help systems for the device drivers IVI C and IVI COM and LabVIEW G l Specifications Data Sheet Follow the Startup Sequence Thi...

Page 8: ...spect for damage After unpacking the module carefully inspect it for any shipping damage Report any damage to the shipping agent immediately as such damage is not covered by the warranty Warranty info...

Page 9: ...instrument or prevent it from moving in the shipping container Styrene pellets can also cause equipment damage by generating static electricity or by lodging in fan motors If any correspondence is req...

Page 10: ...r operation than is required for installation The amount of space listed above is required for installation 2 Note NET Framework Runtime Components are installed by default with Windows Vista Therefor...

Page 11: ...llowing l Agilent IO Library Suite IOLS which includes the Agilent Connection Expert This software must be installed first Version 16 2 or newer of the Agilent IO Libraries Suite is required l Soft Fr...

Page 12: ...e triangle symbol 5 Install the module into the appropriate slot of the chassis by placing the module card edges into the front mod ule guides top and bottom Ensure that the ejector handle is pushed d...

Page 13: ...t This input is AC cou pled and 50 terminated The recommended signal level is 1 V pk pk 4 dBm The clock signal frequency should be half of the desired sampling frequency TRG OUT This MMCX female conne...

Page 14: ...202 module is recognized 3 Select the M9202A module and check that the correct Model Name appears in the Instrument Properties 4 Select the Installed Software tab and review the configuration data as...

Page 15: ...e with the processor controlling it When the SFP is launched it will initiate a self calibration which takes a little over 1 minute Verify that no error is shown in the lower left hand log area The im...

Page 16: ...or 1x BNC MMCX cable 50 Coaxial 100 cm Operational Verification Procedure Do not exceed the maximum power level to the INPUT connector 0 5 W 1 Launch the soft front panel SFP The calibration must succ...

Page 17: ...cilloscope 3 If the problem occurs during Operational Verification disconnect the input signal and note the status of the LED on the front panel it should be GREEN Reconnect the signal and select the...

Page 18: ...ers Manufacturers Group PCIe and PCI EXPRESS are registered trademarks and or service marks of PC SIG Microsoft Windows VisualStudio VisualC VisualC and VisualBasic are either registered trademark or...

Reviews: