Keyscan Inc. – Technical Guide (PC109x - 04.15)
137
Device
Relay Jumper
Status
Possible
TZ
Status
LED
State
N.C. Relay
State
N.O. Relay
State
Accessibility
Relay
Reversed
Activated
-
Accessibility
Relay
Reversed
Normal
-
Elevator Relay
Normal
Unsecured
ON
Elevator Relay
Normal
Secured
OFF
Elevator Relay
Reversed
Unsecured
ON
Elevator Relay
Reversed
Secured
OFF
Legend
LED – On
LED – Off
Manual Output Control – Aux Status Off (Red)
Manual Output Control – Aux Status On (Green)
Relay State Open
Relay State Closed
OCB8 – Relay Jumper in Normal Position
OCB8 – Relay Jumper in Reversed Position
Summary of Contents for CA250B