Keyscan Inc. – Technical Guide (PC109x - 04.15)
42
Figure 29 – Terminate Input Wiring – AI/SI Inputs
to Supervised
Auxiliary Alarm Input
1
to Common Return
1K
Single end of line
supervision
1
to Common Return
1K
Double end of line
supervision
3K
Non-supervised
Notes
Diagram illustrates CA8500B.
Connections also apply to CA250B & CA4500B.
- CA250B
– up to 8 Supervised Auxiliary Alarm Inputs
- CA4500B
– up to 16 Supervised Auxiliary Alarm Inputs
- CA8500B
– up to 16 Supervised Auxiliary Inputs
NC
COM
NC
COM
NC
COM
NC = Normally Closed
to Supervised
Auxiliary Alarm Input
Cut View of CA8500B
Door Inputs - A
RTE Inputs - B
8
7
6
5
4
3
2
1
Common
8
7
6
5
4
3
2
1
AUX Inputs - C
8
7
6
5
4
3
2
1
Common
Common
AUX Inputs - D
16
15
14
13
12
11
10
9
Common
AUX Inputs - E
24
23
22
21
20
19
18
17
KI-00133E-10-13
Supervision level set in Client software:
System VII & Vantage
– Site Unit Setup
Aurora
– Hardware Setup
Supervision level applied to all door inputs, RTE inputs, and auxiliary inputs.