15
1.16 Burner start up counter
– reading of this counter defines start number of the
ignition attempts.
1.17 Boiler on -
the parameter informs the user if the boiler is turned on and allows
him/her to turn it
on or off.
1.18 DHW heating on
– the parameter informs the user if the DHW heating is
turned on and allows him/her to turn it on or off.
1.19 Alarms cancellation.
The parameter enables the user to cancel the alarms recorded in the controller data
storage.
1.20 Burner mode.
INTERMITTENT
– turning off the thermostat will cause the controller to switch into
the POSTCOMBUSTION mode.
CONSTANT
– once the thermostat is turned off, the controller will switch into the
MINIMUM CAPACITY mode instead of the POSTCOMBUSTION (the mode saving
the ignitor).
1.21 SUMMER threshold temperature
– The transition temperature control in
SUMMER mode.
1.22 WINTER threshold temperature
– The transition temperature control in
WINTER mode.