Rack Mounting:
›
Secure the rack ears to each side of the
KD-Pro6x6/8x8CC
with the supplied hardware, then,
fasten the unit to the rack rails with the included machine screws.
About KD-XSWRx
›
Signal Extension:
»
Up to 150 ft. @ 4K 24/25/30(4:4:4)/60(4:2:0) using KD-CAT6STP1X cabling
»
Up to 125 ft. @ 4K 24/25/30(4:4:4)/60(4:2:0) using third-party CAT5e/6 UTP/STP cabling
»
Up to 250 ft. @ 1080p / 1920x1200 using KD-CAT6STP1X cabling
»
Up to 230 ft. @ 1080p / 1920x1200 using third-party CAT5e/6 UTP/STP cabling
›
4K/Ultra HD Resolution:
Support for 4096x2160 or 3840x2160 24/25/30Hz at 4:4:4/8 Bit or
60Hz at 4:2:0/8 Bit
›
HDMI
®
and HDCP Licensing:
Fully licensed and compatible with HDCP 2.2 and HDMI latest
technology such as 4K/UHD 4:2:0/8bit at 60f/s
›
EDID Control:
Internal library features 15 default EDID configurations and native EDID data from
Output/Display devices connected via Rx
›
Full Buffer System
™
:
Manages TMDS re-clocking / signal re-generation, HDCP authentication
with source & display, EDID Control handshake, and Hot Plug control
›
IR Sensor:
Sensor powering via +5V on Rx unit’s IR In port collects line-of-sight IR from remote(s)
without external IR connecting block
›
Up/Down IR:
Two channels of IR enable control to/from connected devices
›
RS-232:
Bi-Directional control to/from on 3.5mm connector
Connections, Buttons and LEDs
Rear Panel Connections:
HDMI Inputs & LEDs
I/O
Ports
HDMI & CAT5e/5 Outputs & LEDs
Operation
Mode
RS-232 Port
POH Power
Main Power
IR Eye
USB
TCP/IP
Connections
›
HDMI Inputs:
Located on the left side of the
back panel. The Inputs have a blue LED that
will illuminate when a source is connected and
synced.
›
HDMI & CAT5e/6 Outputs:
Located in the
middle of the back panel. The Outputs have
a blue LED that will illuminate when a output
device is connected and synced.
›
The
RS-232, Serial IR, Optical IR Sensor,
Operation Mode Switch, TCP/IP, USB and
Power
are located on the right side of the
back panel.
»
Two power connections are necessary. Main Unit power and POH power.
›
I/O Ports:
Located to the right of the Outputs
»
Used for control extension/routing and ARC.
›
The
Operation Mode
switch is used to update the unit’s firmware, which is done via RS-232,
USB or TCP/IP. The firmware version as well as all RS-232 commands is available through the
RS-232 command ‘H’. A detailed list of RS-232 commands are available later in this guide.
›
If newer firmware is made available, complete updating instructions will be included with it. Check
the Key Digital website for any firmware updates.
»
www.keydigital.com/items.asp?ItemCode=KDPro8x8CC&Company=KEY
KD-Pro6x6_8x8CC_Manual.indd 2-3