DosiPump 1000 User Manual 

Page 7 / 24  

Version 1.01E 

2.4 Safety information for the user company 

The superiors of the operating personnel must have understood and must comply with Chapter "Safety 
information" and the aspects of operation relevant to safety. They must ensure that the operating per-
sonnel have understood and follow the safety information. 
Before placing the unit into operation, superiors must check that operation of the D

OSI

P

UMP 

1000 in con-

junction with other installations or system sections cannot pose additional risks and dangers. 
If necessary, additional technical safety instructions must be drawn up by superiors. In order to preclude 
the possibility of residual risks and dangers, the company using the D

OSI

P

UMP 

1000 may need to draw 

up in-company instructions and have receipt of these instructions confirmed by the personnel responsi-
ble. Moreover, the user company must stipulate the scopes of authority for working with the D

OSI

P

UMP 

1000 so that there are clear scopes of authority in relation to technical safety aspects. 

2.5  No arbitrary conversion work or modification work 

No modifications may be made to the D

OSI

P

UMP 

1000. In particular, defective components may be re-

placed only by original parts. Neither the design nor the technical safety systems of the D

OSI

P

UMP 

1000

may be modified without our express consent. In particular, no modifications to safety facilities are per-
mitted. Modifications of any nature will exempt us from liability for resultant damage and injury. 

2.6  Supplementary safety information 

1. The 

D

OSI

P

UMP 

may be used only for the intended application as stated and for no other purposes.  

2.  Maintenance work and repair work may be carried out only by qualified staff. 
3.  The unit must be installed in such a manner that the On/Off switch is easily accessible at all times. 
4.  Should a situation arise in which safe operation of the D

OSI

P

UMP 

1000 can no longer be guaranteed, 

the unit must be placed out of operation and locked until it can be repaired by qualified staff. Such a 
situation must be assumed if: 
- there is visible damage to the D

OSI

P

UMP 

1000, 

- the D

OSI

P

UMP 

1000 is no longer working or 

- the mains-circuit over current release trips. 

5. Disconnect 

the 

D

OSI

P

UMP 

1000 from the mains power supply before moving it to a new location. 

6.  Connect the power cables of the D

OSI

P

UMP 

1000 only to a fully earthed mains system in order to 

avoid electric shock. Do not use adapters for plugs and do not remove earthing connections from 
cables. If an extension cable has to be used, please use only three-core cable with correctly earthed 
plugs. 

7.  Ensure that all cables and tubes are laid in a safe area to prevent the risk of tripping over them.
8.  Do not spill food or liquids on the D

OSI

P

UMP 

1000. Please read the technical guide if the D

OSI

P

UMP 

1000 requires cleaning. 

2.7  Warranty and liability 

BioTool Swiss AG provides warranty for this unit covering defects in relation to both components and 
design. The unit has been thoroughly inspected in order to ensure that it complies with the specifica-
tions published. BioTool Swiss AG guarantees that this unit will remain free of defects for a period of 18 
months as of the date of delivery. This warranty shall be rendered null and void if the unit is not operat-
ed by a trained person in accordance with the instructions supplied by BioTool Swiss AG or if an un-
qualified person attempts to repair the unit.  

NOTE 

Parts subject to wear are not covered by warranty. 

Summary of Contents for 730'000

Page 1: ...DosiPump 1000 User Manual Page 1 24 Version 1 01E DOSIPUMP DP 1000 DosiPump DP1000 Item 730 000 DosiPump DP1000 Fast Item 740 000 USER MANUAL 1 01 E Version 2010 2011...

Page 2: ...ING 8 3 2 MAINS CONNECTION 8 3 3 INSERTING THE TUBE FITTING IN THE PUMP 8 3 4 METAL BAR FIXATION MAKING THE STURDY HOUSING A STABLE STAND 8 3 5 MAIN SWITCH 8 4 OPERATION OF THE DOSIPUMP 1000 9 4 1 FUN...

Page 3: ...he Overview contains general information on the DOSIPUMP 1000 the intended application and the basic concept Safety Information The DOSIPUMP DP1000 safety information Commissioning The steps and prepa...

Page 4: ...nge in only 1 unit Precision and reproducibility are depending the ratio between tube and desired volume The smaller the tube the higher the precision and reproduci bility but the smaller the pump spe...

Page 5: ...epts tube sizes from 2x6mm for small doses up to a double tube set of 8x12mm for fast dosing DosiPump is build in a stable stainless steel housing offering IP64 splash water resistance DosiPump DP1000...

Page 6: ...chemicals DosiPump is not an EX Approved WARNING We are unable to guarantee operability and functional safety of the unit if the ambient conditions applicable to the location are not complied with 2 2...

Page 7: ...her purposes 2 Maintenance work and repair work may be carried out only by qualified staff 3 The unit must be installed in such a manner that the On Off switch is easily accessible at all times 4 Shou...

Page 8: ...ese values Connect the power cable of the DOSIPUMP 1000 only to a fully earthed mains power supply system in order to avoid electrical shock Do not use adapters for the plugs and do not remove the ear...

Page 9: ...Pump speed ml min the pump direction Antidrop angle defined pump head pullback pause before next dose 4 4 All Programmes require a calibrated tube DosiPump allows 8 Tube sets to be cal ibrated and sel...

Page 10: ...to continue 2 3 4 DosiPump allows direct dosing straight from the main screen continuous pump mode No need for previous program setting The speed and the pump direction can be selected Select Pump di...

Page 11: ...irection front backside Anti Drop Angle in Delay between singe doses sec Start Program 4 5 Select the number of repetitive dosings or endless repeats manual stop required Tube Filling option before pr...

Page 12: ...fore DosiPump starts the selected program the cycle repetition screen appears automatically Select number or cycles repetition of complete program Alternatively select Endless repetitions repeats unti...

Page 13: ...opens Selects the tube 1 8 Each single Dosing Step consists of all individual variables a dosing can consist of Opens the Edit Mode of the selected step Start Stop dispensing this program Volume Pump...

Page 14: ...se as possible This based on the physical difference any tube offers regarding pump expansion relaxation between the pump rolls Note The pump direction in the calibration mode is CCW Info The pump cal...

Page 15: ...e Touch Screen does not react fast and appropriate anymore it may be necessary to recalibrate the touch screen Touch at the top left hand corner Follow the at the bottom right hand corner 4 7 4 Displa...

Page 16: ...three parts water Deionised water Soft lint free cleaning cloth and paper tissues WARNING Do not use cleaning agents containing acetone or other aggressive cleaning agents nitrocellulose thinners WAR...

Page 17: ...porates troubleshooting routines which can be used to correct certain problems without action on the part of after sales servicing technicians If a problem occurs on the DOSIPUMP 1000 the unit attempt...

Page 18: ...urring during operation Symptom Possible cause Correction Fault signal Pump blocked The culture medium in the tube is too viscous You have used a tube which is too large Remove the tube and run the pu...

Page 19: ...act 1 Pin 3 Footswitch contact 2 Pin 2 29 V The two footswitch contacts are designed as normally open contacts NO 2 PC printer connection pin assignment RS232 Version P PI Pin 1 RxD Pin 2 TxD Pin 3 GN...

Page 20: ...everse angle of pump head Display 240 x 128 pixels with LED backlighting Sound pressure level 79 dB A Pollution severity II Safety class IP 64 Ambient temperature 5 C to 45 C also during transport Uni...

Page 21: ...0 Stage bar stainless steel 101052 Silicone tubing 3x7 mm roll of 25m 101054 Silicone tubing 5x9 mm roll of 25m 101055 Silicone tubing 6x10 mm roll of 25m 101056 Silicone tubing 7x10 mm roll of 25m 10...

Page 22: ...4 Version 1 01E 6 2 Reproducibility and Precision Data from BioTool test lab June 25th 2010 DP1000 Serial 730 13 00014 DP1000 Fast Serial 740 13 00016 Test with tab water No evaporation protection oil...

Page 23: ...automatic updates and product infor mation from BioTool AG 6 5 Contacts Feedback Sales Marketing Manufacturing site Please place your feedback with you local supplier your local service partner BioTo...

Page 24: ...DosiPump 1000 User Manual Page 24 24 Version 1 01E...