4.6 Normal mode visualization
In “NORMAL MOD
E”, when the installation is powered normally, the 2-digit LCD displays rotates and after 30 sec. will turn off
4.5 Wiring diagram
WARNING - Before making connections verify that the installation is not powered
Wiring diagram photocell, safety connection STOP and step/step command P/P
The emergency STOP contact must be connected between EMRG and GND (contact normally closed NC)
The step/step contact SBS must be connected between DOOR and GND (contact normally open NA)
4.7 Customizing the installation
Programming
Preparation
A. Gently move the door to activate the carriage so that the automation system can guide the door
B. Power on. The light will turn on, the unit provides a single audible signal and the display indicates”0” in cycles.
Attention: If programming is not complete, the settings will be cancelled automatically. If incorrect information has been pro
-
grammed, power off and then power back on, referring to the following.
4.8 Setting of opening limit
Press the key “P” for
5 seconds
Press”+”
Or press “-”
The unit emits 1 beep and “1”
is displayed.
Door opening
Door closing
Press “P”, “1” flashes
When the door opens and reaches
the ideal position, press the key “P”
to save the information.
Warning: the saved information has no effect if this procedure is used for setting the limit of closing
1
2
4
3
5
D
escription of the buttons
1 - P function button
2 - S memorization of remotes button
3 - + parameter increase button
4 - - parameters decrease button
5 - Display
COMMON
2
3 4
1
1 2
TX
TX
RX
RX
NC
24Vac/dc
- +
24Vac/dc
- +
Receiver
F2
F1
T2.5A
250V
T2.5A
250V
Display
Limit switch
Encoder
+24V
Photocell.
-Common
STOP
COM
SBS
ANT GND
DOOR
GND
24VDC
LAMP
GND
IR1
24V
EMRG