Certificate  

of Conformity &  

Warranty Registration

This instrument has been calibrated 

using equipment which has itself been 

calibrated to standards traceable to 

International Standards monitored by 

BIPM (International Bureau of Weights  

and Measures)

This certificate guarantees that the 

product has been fully inspected and 

conforms to all the relevant published 

specifications.

Free Two Year Warranty

Kewtech's Two Year Warranty enhances 

the customers' legal rights/ it covers all 

manufacturing defects for a two year 

period but Kewtech reserves the right to 

exclude abuse or accidental damage.

To register your free guarantee simply go 

to kewtechcorp.com - the link is on the 

home page.

Re-calibration Service

Regular re-calibration is recommended 

for this instrument. Kewtech recommends 

that with normal use the instrument 

is calibrated at least once in every 12 

month interval.

When the instrument is due for 

re-calibration return it to the address 

below marked for the attention of the 

Calibration Department.

Kewtech Corp Ltd

Shaw Wood Business Park

Shaw Wood Way

Doncaster DN2 5TB

t: 01302 761044

Summary of Contents for KEW 2200

Page 1: ...nstruction Manual COM V HOLD OFF A V V 600V 1000A CAT II 600V CAT III 300V CAT III digital clamp meter KEW 2200 Current Sensor Trigger Function Switch V Terminal COM Terminal LED Data Hold Key Mode Ke...

Page 2: ...0 000 0 005 4 199V 1 8 rdg 7dgt 45 65Hz 2 3 rdg 8dgt 65 500Hz 40V 3 20 41 99V 400V 32 0 419 9V 600V 320 629V DC V Auto Range Range Accuracy 400mV 0 0 419 9mV 1 4V 0 320 4 199V 1 0 rdg 3dgt 40V 3 20 41...

Page 3: ...47V typ 40k 40M Range Input protective voltage AC DC 600V 10 sec Measuring method Dual integration Over range indication OL Measurement cycle 2 5 times per second Applicable Standards IEC EN 61010 1 6...

Page 4: ...AC 5320Vrms 5sec between current sensor and enclosure AC 3540Vrms 5sec between circuit and enclosure Insulation resistance 100M 1000V between enclosure and electrical circuit Operating temperature and...

Page 5: ...guaranteed when the measured object is placed at the centre zone A of the Current Sensor In zone B 4 of tolerance should be added to the specified accuracy In zone C measured values should be conside...

Page 6: ...C V DC V Measurement DANGER 600V Never make measurement on a circuit in which voltage over 600V exists Black test lead ACV Red test lead DCV Black Red digital clamp meter KEW 2200 digital clamp meter...

Page 7: ...t in over 600V exists 5 Resistance Continuity Measurement WARNING Never use the instrument on an energized circuit Beeps when less than 50 30 Test lead Test lead Resistance Continuity LCD Press digita...

Page 8: ...nual for safe operation of the instrument It is essential to read the instructions wherever the symbol appears in the manual DANGER is reserved for conditions and actions that are likely to cause seri...

Page 9: ...from the service drop to the service entrance and to the power meter and primary over current protection device distribution panel Current measurement section of this instrument is designed for CAT II...

Page 10: ...instrument Firmly attach the Caps to the test leads when performing measurements at CAT III or higher test environment When the KEW2200 and the test leads are combined and used together whichever is...

Page 11: ...mpletely exhausted the LCD goes blank without showing mark Do not try to replace the batteries if the surface of the instrument is wet Disconnect the test leads from the object under test and power of...

Page 12: ...e customers legal rights it covers all manufacturing defects for a two year period but Kewtech reserves the right to exclude abuse or accidental damage To register your free guarantee simply go to kew...

Reviews: