background image

kewtechcorp.com

WARNING

•  Read through and understand the 

instructions contained in this manual before 

using the instrument.

•  Keep the manual at hand to enable quick 

reference whenever necessary.

•  The instrument is to be used only in its 

intended applications.

•  Understand and follow all the safety 

instructions contained in the manual.

•  It is essential that the above instructions 

are adhered to.

•  Failure to follow the above instructions 

may impair the protection provided by the 

instrument and test leads, and may cause 

injury, instrument damage and/or damage 

to equipment under test.

The symbol       indicated on the instrument 

means that the user must refer to the related 

parts in the manual for safe operation of 

the instrument. It is essential to read the 

instructions wherever the symbol      appears 

in the manual.

DANGER is reserved for conditions and 

actions that are likely to cause serious or 

fatal injury.

WARNING is reserved for conditions and 

actions that can cause serious or fatal 

injury.

CAUTION is reserved for conditions 

and actions that can cause injury or 

instrument damage.

6. Safety Warnings

This instrument has been designed, 

manufactured and tested according to IEC 

61010: Safety requirements for Electronic 

Measuring apparatus, and delivered in the best 

condition after having passed final inspection. 

This instruction manual contains warnings and 

safety rules which must be observed by the 

user to ensure safe operation of the instrument 

and retain it in a safe condition. Therefore, 

read through these operating instructions 

before using the instrument.

Summary of Contents for KEW 2200

Page 1: ...nstruction Manual COM V HOLD OFF A V V 600V 1000A CAT II 600V CAT III 300V CAT III digital clamp meter KEW 2200 Current Sensor Trigger Function Switch V Terminal COM Terminal LED Data Hold Key Mode Ke...

Page 2: ...0 000 0 005 4 199V 1 8 rdg 7dgt 45 65Hz 2 3 rdg 8dgt 65 500Hz 40V 3 20 41 99V 400V 32 0 419 9V 600V 320 629V DC V Auto Range Range Accuracy 400mV 0 0 419 9mV 1 4V 0 320 4 199V 1 0 rdg 3dgt 40V 3 20 41...

Page 3: ...47V typ 40k 40M Range Input protective voltage AC DC 600V 10 sec Measuring method Dual integration Over range indication OL Measurement cycle 2 5 times per second Applicable Standards IEC EN 61010 1 6...

Page 4: ...AC 5320Vrms 5sec between current sensor and enclosure AC 3540Vrms 5sec between circuit and enclosure Insulation resistance 100M 1000V between enclosure and electrical circuit Operating temperature and...

Page 5: ...guaranteed when the measured object is placed at the centre zone A of the Current Sensor In zone B 4 of tolerance should be added to the specified accuracy In zone C measured values should be conside...

Page 6: ...C V DC V Measurement DANGER 600V Never make measurement on a circuit in which voltage over 600V exists Black test lead ACV Red test lead DCV Black Red digital clamp meter KEW 2200 digital clamp meter...

Page 7: ...t in over 600V exists 5 Resistance Continuity Measurement WARNING Never use the instrument on an energized circuit Beeps when less than 50 30 Test lead Test lead Resistance Continuity LCD Press digita...

Page 8: ...nual for safe operation of the instrument It is essential to read the instructions wherever the symbol appears in the manual DANGER is reserved for conditions and actions that are likely to cause seri...

Page 9: ...from the service drop to the service entrance and to the power meter and primary over current protection device distribution panel Current measurement section of this instrument is designed for CAT II...

Page 10: ...instrument Firmly attach the Caps to the test leads when performing measurements at CAT III or higher test environment When the KEW2200 and the test leads are combined and used together whichever is...

Page 11: ...mpletely exhausted the LCD goes blank without showing mark Do not try to replace the batteries if the surface of the instrument is wet Disconnect the test leads from the object under test and power of...

Page 12: ...e customers legal rights it covers all manufacturing defects for a two year period but Kewtech reserves the right to exclude abuse or accidental damage To register your free guarantee simply go to kew...