■ Communication setting

Set the port for communication with the PC software.

Either the USB port or LAN port can be selected.

For the LAN port, LANTRONIX’s XPort is employed.

For how to use the PC software, refer to the PC software operating manual.

*  To cancel the setting during operation, press the [EXIT] key. Then, the previous screen will be restored.

Step

Display

Operation

1 . C H

P A R A M E T E R

2 . C H

D U P L I C A T E

3 . C H

R E S E T

4 . C O M

S E T T I N G

5 . P A S S

C O D E

6 . X P O R T

S E T U P

M O D E

●  Select the communication setting.

Press the [MENU] key, and enter the pass code.
Move the cursor to [4. COM SETTING] with [

]/[

] key. 

Then, press the [ENTER] key to set the code.

4 . C O M

S E T T I N G

C O M

U S B

X P O R T

O K

C A N C E L

4 . C O M

S E T T I N G

C O M

U S B

L A N

●  Set the communication.

Either [USB] or [LAN] can be selected by pressing the 
[ENTER] key while [COM] is selected.

Select [USB] or [LAN] using

 [

]/[

key, and press the 

[ENTER] key to set.

4 . C O M

S E T T I N G

C O M

U S B

X P O R T

O K

C A N C E L

4 . C O M

S E T T I N G

M A C

A D D R E S S

× × × × × × × × × × × ×

I P

A D D R E S S

× × × . × × × . × × × . × × ×

O K

●  Check the XPORT setting.

The XPORT setting can be checked by pressing the 
[ENTER] key while [XPORT] is selected.

*  Checking the XPORT setting is necessary when using the 

LAN port for communication. For details, refer to the PC 

software operating manual (2-2. Setting XPORT).

MAC ADDRESS and IP ADDRESS will be displayed.
Pressing the [ENTER] key will restore the communication 
setting screen.

4 . C O M

S E T T I N G

C O M

U S B

X P O R T

O K

C A N C E L

4 . C O M

S E T T I N G

C O M

U S B

X P O R T

O K

C A N C E L

●  Save the communication setting.

When setting is completed, move the cursor to [OK] with [

key. Pressing the [ENTER] key will restore the menu screen 
after saving the communication settings.

*  The menu screen will be restored if the [ENTER] key is 

pressed while [CANCEL] is selected.

*  Note that if the [ENTER] key is pressed while [CANCEL] is 

selected, the setting will not be saved.

Summary of Contents for KB-270

Page 1: ...NIR Composition Analyzer KB 270 Operating Manual Thank you for purchasing this product Please read the operating manual carefully and use this product properly...

Page 2: ......

Page 3: ...3 7 Making the calibration curve 14 7 1 Setting the measurement range and the number of samples 14 7 2 Setting the sampling times 14 7 3 Preparing the samples 14 7 4 Moisture preparation 15 7 5 Measur...

Page 4: ...dor Do not allow the unit to come in contact with water This unit is not waterproof Do not allow water or other liquids to get into the unit s enclosure as this may lead to electric shock or malfuncti...

Page 5: ...t sunlight electromagnetic interference corrosive gases or large amounts of dust Place the unit on a flat and stable surface where it will not be subjected to significant vibration during use When mov...

Page 6: ...composition measurements It measures the near infrared absorption of six wavelengths of the measuring object and converts the obtained data to the composition The multiple compositions four compositi...

Page 7: ...ual this document PC software USB cable VZC61 Using the supplied PC software various operations such as zero adjustment measurement setting the calibration curve device setting and maintenance can be...

Page 8: ...content Channel number Channel name Composition Absorbance Operating temperature range 5 to 35 C no condensation Power supply 100 120 V AC 220 240 V AC 50 60 Hz Power Consumption 50W Dimensions and w...

Page 9: ...A key Used for measurement TABLE key Used to set ON OFF of the rotation table ZERO key Used for zero adjustment EXIT key Used to exit the operation MODE key Used to select the measurement mode CH key...

Page 10: ...justment will proceed while displaying the absorbance in real time When the calibration is completed the initial screen will be restored If the power is cycled repeat the operation from step 6 Make su...

Page 11: ...surement error tends to occur depending on the light absorption characteristics of the plastic bag 3 Polyethylene sheet only for moisture Rice ball boiled noodle and uncooked noodles etc For large sol...

Page 12: ...n When rotating the table using a 90 mm of Petri dish use the sample cell holder Also use the light shielding cover to prevent falling off When using the polyethylene sheet prevent the sheet from bein...

Page 13: ...e saturated sampling amount If the sampling amount is sufficiently prepared set the sampling amount more than the absorbance saturated sampling amount Refer to P 30 Remarks if the absorbance saturated...

Page 14: ...This is called calibration curve The calibration curve differs depending on the measuring object Therefore it is required to make calibration curve per object in advance This unit is capable of makin...

Page 15: ...the obtained data as the standard composition As the over drying method the official method or a measurement using an infrared moisture analyzer is available Note that the sample cannot be reused in...

Page 16: ...ing 1234 Present ON 1 2 3 4 Present OFF Absent Setting not available When changing the measurement channel the channel that has no coefficient or the one whose display setting of all four compositions...

Page 17: ...7 6 X 3 0 5 1 5 4 X 4 0 4 1 8 1 X 5 0 1 9 8 4 X 6 0 1 2 9 6 Set the sample to cover up the measurement window The continuously measured absorbance will be displayed Set the smoothing value as require...

Page 18: ...he light shielding cover and set the zero adjustment plate onto the rotation table of the unit Then close the cover Perform zero adjustment Press the ZERO key The zero adjustment screen will be displa...

Page 19: ...essing the ENTER key will enable the setting Set the item referring to the corresponding pages Display Contents Page 1 C H P A R A M E T E R Setting the channel parameter P 20 2 C H D U P L I C A T E...

Page 20: ...A S N T 2 C O M P P A R A M E T E R C A N C E L Enter the smoothing value of continuous measurement Select the smoothing value 0 to 5 using key and press the ENTER key to set A channel identification...

Page 21: ...set To enter or edit Move the cursor using the EXIT and ENTER keys Input the composition name from the 1st character using the numeric keypad and move the cursor one by one with the Enter key Up to 8...

Page 22: ...N C E L Enter the offset value To correct enter the value in the same procedure as step 11 Enter 0 if correction is not needed 1 0 1 F L O U R C O M P P A R A M E T E R 1 M O I S T U R E O F F S E T...

Page 23: ...uplication destination channel Move the cursor to the destination of channel duplication with key and press the ENTER key to set Press the ENTER key when the confirmation screen is displayed The menu...

Page 24: ...0 2 F L O U R 2 12 3 4 0 3 C O R N 1 12 4 0 4 C O R N 2 1 0 5 B U T T E R 1 2 3 0 6 F L O U R 1234 0 7 Select the channel to initialize Move the cursor to the channel to initialize with key Then press...

Page 25: ...M is selected Select USB or LAN using key and press the ENTER key to set 4 C O M S E T T I N G C O M U S B X P O R T O K C A N C E L 4 C O M S E T T I N G M A C A D D R E S S I P A D D R E S S O K Che...

Page 26: ...5 P A S S C O D E N E W C O D E 1 2 3 4 Set the pass code After four digits are input the cursor will move to the right end automatically Pressing the ENTER key will restore the menu screen after savi...

Page 27: ...d off Be careful of the edges inside the main unit Otherwise it may cause an injury etc 11 Maintenance Step Operation Rear of the main unit Turn off the power and disconnect the power cable The lamp h...

Page 28: ...11 3 Consumable parts To use the unit in the best accuracy it is recommended to replace consumable parts at an interval of two years Other than the light source lamp do not replace the consumable part...

Page 29: ...k the ambient temperature E 05 Sample low reflection The reflectivity of sample is low and the signal level is below the requirement When sample is not set on the measurement window Set the sample and...

Page 30: ...absorbance saturated sampling amount While the near infrared from the bottom passes through the sample the displayed value will continue to fluctuate If the following is met making calibration curve...

Page 31: ...31...

Page 32: ...rts depicted in this user manual may not appear exactly as their actual counterparts but this does not affect their operation or functionality This user manual was intended to be written as clearly an...

Reviews: