background image

Pre-Installation

Warning: 

Turn OFF electrical power to all circuit breakers feeding into the panel before installing  

or servicing this product.

Warning:

 Improper use or installation can cause SERIOUS INJURY, DEATH, OR LOSS/ DAMAGE  

OF PROPERTY.

This device should be protected by a 20 A circuit breaker.

This device includes a two-way radio. For optimal performance and signal integrity:

• 

Do not install in third-party metal enclosures

• 

Use non-metal enclosures (e.g. plastic, fiberglass or PVC)

Product is plenum-rated for non-air-handling spaces.

Product is direct-insulation contact rated.

If placed in enclosure alongside other electrical components, take necessary precautions regarding 
operating temperatures.

Product is UL surface-mount listed. Does not require a dedicated enclosure.

This product contains both class 1 and class 2 electrical connections. The sections are physically 
separated by a barrier. MAINTAIN PHYSICAL SEPARATION BOTH INSIDE AND OUTSIDE OF DEVICE IN 
ACCORDANCE WITH ELECTRICAL CODES.

This device must be installed by a licensed electrician in accordance with all national and local codes.

6 | 

N3

 INSTALLATION GUIDE

770-000014-01 r09

© 2019 Ketra, Inc. All rights reserved

Summary of Contents for N3 Satellite

Page 1: ...N3 SATELLITE Installation Guide...

Page 2: ...es uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee th...

Page 3: ...e Installation 6 Pre Installation Instructions 7 Installation 8 Diagnostic Colors Requires Emitter 8 Physical Mounting 9 Installation 10 Overview of Third Party Controls 12 Warranty Tech Support 13 3...

Page 4: ...stronomical time clock functionality The N3 s wireless connectivity enables its installation in multiple convenient locations fig 1 AC Power In USB Firmware Updates DMX Out Status Indicators Multifunc...

Page 5: ...nnections Class 2 AC Power In 3 Conductor 120 277 V 60Hz 10 16 AWG Line Neutral Ground AC Power Out 4 Line Standard Ketra Leader Cable or 10 16 AWG Connections Class 2 Multifunction I O 4 channels 16...

Page 6: ...t is plenum rated for non air handling spaces Product is direct insulation contact rated If placed in enclosure alongside other electrical components take necessary precautions regarding operating tem...

Page 7: ...ending upon topology and materials within the space range may be limited Avoid metal obstructions Walls may impact communication depending upon construction method and materials For complete design sp...

Page 8: ...9 countersunk head This product has a suggested clearance to ensure access to all connections and all analog user interface switches see fig 3 fig 2 fig 3 AC Mains IN TRIAC Control LN L N Power Signal...

Page 9: ...m lid see fig 4 2 Remove plastic plugs from knock outs as required see fig 5 3 Mount box to surface with appropriate fasteners Note inner diameter of hole is 3 16 in 4 76 mm see fig 6 Screws Main Cove...

Page 10: ...nections to the AC Mains In section connecting to appropriate line neutral and ground terminals Note wire strip length is 0 47 inches 12 mm 2 Insert appropriate conductors from Mains Power see fig 8 B...

Page 11: ...nnecting to appropriate line neutral and ground terminals Note Details on connections with the linear product family available in their respective installation guides 3 Insert appropriate conductors f...

Page 12: ...it or NM type cable as appropriate Note Acceptable wire is both solid core and stranded Gauge range is 1 29 mm2 1 31 mm2 0 511 mm2 0 205 mm2 2 Open appropriate terminals by depressing appropriate term...

Page 13: ...ty For questions and technical support please contact 844 588 6445 ketrasupport lutron com Ketra and KetraNET are trademarks or registered trademarks of Lutron Ketra LLC in the US and or other countri...

Page 14: ...6231 E Stassney Ln Bldg 13 Suite 400 Austin TX 78744 ketra com 512 872 4349 770 000014 01 r09...

Reviews: