INSTALLATION
Installation
WARNING:
DO NOT CONNECT AC SUPPLY TO TERMINALS MARKED “TRIAC CONTROL.” Triac Control
feature is not supported.
STEP 1
Connect AC supply
Use conduit or NM type cable as appropriate.
Note:
Acceptable wire is both solid core and stranded. Gauge range is 2.59 Ø[mm]/5.26 Ø[mm2] -
1.29 Ø[mm]/1.31 Ø[mm2].
1. Open appropriate terminals by flipping orange levers into UP position. (see fig. 7) Make connections to
the “AC Mains In” section connecting to appropriate line, neutral and ground terminals.
Note:
wire strip length is 0.47 inches (12 mm).
2. Insert appropriate conductors from Mains Power. (see fig. 8)
Black conductor goes to “L” terminal (Black).
White conductor goes to “N” terminal (White).
Green conductor goes to “
” terminal (Green).
Note:
Conductor colors are not always as listed. These colors vary depending on your wiring setup.
To ensure the correct wiring, consult a professional electrician.
fig. 7
fig. 8
continued on next page
10 |
N3
INSTALLATION GUIDE
770-000014-01 r09