INSTALLATION
fig. 9
fig. 10
STEP 2
Connect power and signal output to linear luminaires.
Note:
Details on G2 linear connections available in G2 Installation Guide.
1. Open appropriate terminals by flipping orange levers into UP position (see fig. 10).
2. Make connections to the “Power and Signal OUT” section connecting to appropriate line, neutral and
ground terminals.
Note:
Details on connections with the linear product family available in their respective installation guides.
3. Insert appropriate conductors from leader cable (see fig. 9):
Black conductor goes to “L” terminal (Black).
White conductor goes to “N” terminal (White).
Green conductor goes to “
” terminal (Green).
Red/Purple conductor goes to the “S” terminal (Purple).
continued on next page
11 |
N3
INSTALLATION GUIDE
770-000014-01 r09