background image

7

7

Time unit: seconds (accu-

racy depending on posi-

tion of the decimal point*)

Time unit: minutes (accu-

racy depending on posi-

tion of the decimal point*)

Time unit: hours (accura-

cy depending on position

of the decimal point*)

Time units:

Hours:Minutes:Seconds

(decimal point setting is

ignored)

4.4 Operating mode

*0, 0.1, 0.01, 0.001 means: time measurement in

0, 0.1, 0.01, 0.001 time units

4.5 Decimal point

The decimal point defines

the resolution of the pro-

grammed time unit.

0

1

0.0 1/10 (0,1)

0.00 1/100 (0,01)

0.000 1/1000 (0,001)

4.6 SET/RESET mode

manual reset via the red

SET/RESET key and 

electrical reset via the

SET/RESET input

no reset (red SET/RESET

key and SET/RESET

input locked)

only electrical reset via

the SET/RESET input

only manual reset via the

red SET/RESET key

4.8 End of programming

The programming routine

is repeated once more.

The values set until now

can be checked and mod-

ified.

The programming routine

wil be left and all values

set will be stored as new

parameters.

Afterwards the device is

ready for operation.

4.8 SET value

The device will be set to

the set point by pressing

the red SET/RESET key

or activating the

SET/RESET input.

SET value 0 ...999 999 or

99.59.59 (number of deci-

mal places depends on

the decimal point option)

5. Technical data

Supply voltage

DC power supply:

10 ... 30 V DC/max. 40 mA

with inverse-polarity protection

Display:

6 digits, red 7 segment 

LED display, height 8 mm

Data retention:

EEPROM

Polarity of the inputs:

Programmable, npn or pnp

for all inputs

Input resistance:

appr. 5 k

Ohm

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Summary of Contents for 521K

Page 1: ...astics paper glass textile and other processing indus tries Over voltages at the terminals of the digital dis play must be kept within the limits in Category II If the digital display is used to monit...

Page 2: ...r Continued in point 4 of 522K on page 4 Operating mode time meter Continued in point 4 of 523K on page 6 Pulse counter Position indicator 521K 524K Operating mode pulse counter 1 Description 6 digit...

Page 3: ...ach pulse edge of INP A and INP B will be counted 4 3 Input mode 4 4 Multiplying factor It can be set from 00 0001 up to 99 9999 The decimal point is set to 4 decimal places 0 is not accepted 4 7 SET...

Page 4: ...ter Red LED display character height 8 mm Display range from 0 to 999 999 Leading zeros suppression Programming via two setting keys on the front side During programming the display guides the user wi...

Page 5: ...to 4 decimal places 0 is not accepted 4 4 Dividing factor 4 6 Display mode Value conversion and display in 1 s Value conversion and display in 1 min 4 7 Max time to wait until 0 is displayed This par...

Page 6: ...while the count is active Programming via two setting keys on the front side During programming the display guides the user with text prompts Time meter operating modes Counting while INP B is inactiv...

Page 7: ...RESET input locked only electrical reset via the SET RESET input only manual reset via the red SET RESET key 4 8 End of programming The programming routine is repeated once more The values set until n...

Page 8: ...nsitivity Low 0 2 V DC High 4 30 V DC Pulse shape any Schmitt Trigger inputs Optocoupler output optional NPN optocoupler with open collector and open emitter max switching performance 30 V DC 10 mA at...

Page 9: ...9 9 8 Dimensions Panel cut out 22 2 0 3 x 45 0 6 mm Front bezel Counter sinking Af3 DIN 74 1...

Reviews: