Instructions for Use
Electronic Presetting Counter
E5148C1400

1. Inputs 

1.1 Reset Input*

This optocoupler input is wired in parallel with the red
SET key and it sets the counter to zero in the up-mode
(incrementing), to the presetting in the down-mode
(decrementing). 

1.2 Count Input*

Optocoupler input damped to 25 Hz for DC or AC voltage. 

* Note:

The reset input (pin 6) and the count input (pin 5) are
op tocoupler inputs with a common connection (pin 7)
and must be actuated with the same polarity. 

1.3 Keyboard Interlock Input 

If this input (pin 2) is connected to 3V DC (pin 1), the
front keys are locked (including the SET key).

2. Output

Relay with potential-free contact programmable as NO or
NC contact (NO = normally open, NC = normally closed).
In the up-mode the relay is active at ≥ the presetting, in
the down-mode at ≤ zero. With automatic repetition the
output signal is a timed signal programmable between
100 msec. and 500 msec. in steps of 100 msec. When
the relay is active, a colon will appear at the bottom left of
the display. The switching frequency of the output relay
must not be higher than 4 Hz. 

3. Setting the operating mode and
operational parameters 

3.1 When installing the unit for the first time or after a
battery change lasting more than 7 minutes, the counter
is set automatically to the programming mode and the 5
parameters must be selected (see 4.2). The parameters
may also be changed during the operation run.
However, this can be achieved only in the programming
mode. In order to reach this mode the following keys
must be depressed simultaneo usly (for safety reasons):
RESET key, the keys of de cade 5 and 6. On the lower
line of the display the message “INIT” appears together
with a down-coun ter subtracting from 5 to 0 in steps of
seconds. If wi thin this period the depressed keys are
released, the previous operating mode will become
active again. If the keys are released after reaching
zero, the first parameter is activated and displayed. 

3.2 Setting the Operational Parameters

The key of the first decade allows the user to select the
requested function within the parameters (e.g. add/
subtract) and the 6th decade-key selects the next
parameter. After the last parameter “dP”, the program
jumps to the beginning. To leave this program rou tine
the user must step through all parameters (from the
beginning to the end) with NO CHANGES at all. 

Note:

Whenever this routine is selected the program will jump
to the beginning, the previous parameters will get lost
and the count as well as the preset values are zeroed. 

4. Operating the counter

4.1 Setting or resetting

Press the red SET button or apply a pulse to the reset
input to set the counter to zero in the accumulating
mode to presetting in the subtracting mode.

4.2 Preset Mode

Presetting is indicated on the lower row of digits. To set
it, use the 6 presetting buttons assigned to each
decade. The set value will be accepted with the next set
or reset operation. 

4.3 Overflow and underflow 

In the accumulating mode the overflow is 999999 to 0;
in the subtracting mode it is 0 to 999999. The output
signal remains unaffected. 

4.4 Lo-Bat indicator 

When the battery charge is too low, “Lo-bat” appears in
the lower display. This flashes in a two-second rhythm.
When “Lo-bat” is indicated, the batteries should be ex -
changed as soon as possible. 

4.5 Changing the batteries 

Push the battery cover back and remove the batteries,
making certain that polarity is correct (observe “–”
terminal on PCB). 

Note:

Changing the batteries should not take longer than 2
min., otherwise the count and preset values as well as
the parameters will get lost and therefore must be set
again (see 3.). 

5. Terminal block 

Terminal assignment

Terminal No.

7

common AC/DC-input for terminals
6 and 5

6

AC/DC optocoupler reset-input

5

AC/DC optocoupler count-input

4

relay contact

3

relay contact

2

keyboard interlock-input

1

+3V DC for terminal 2

MN05401013E:MN05401013E  2/9/07  11:58 AM  Page 1

Summary of Contents for E5-148-C1400

Page 1: ...will become active again If the keys are released after reaching zero the first parameter is activated and displayed 3 2 Setting the Operational Parameters The key of the first decade allows the user to select the requested function within the parameters e g add subtract and the 6th decade key selects the next parameter After the last parameter dP the program jumps to the beginning To leave this p...

Page 2: ...act min switching current 10 mA max switching capacity 30V DC 2 A 230V AC 0 5 A Reaction time of the output 20 ms Noise immunity To VDE 843 Part 4 Severity 3 Ambient temperature 10 to 50 C 14 to 122 F Storage temperature 20 to 60 C 4 to 140 F Weight appr 80 g 2 82 oz Front panel rating IP65 Finish housing black Manufacturer programmed Counting mode up Autom repetition no Relay contact NO normally ...

Page 3: ...vamente la modalidad de funcionamiento que estaba anteriormente Si se sueltan las teclas al llegar a 0 entonces estará activado el ajuste de los parámetros y se indicará en el display el primer parámetro 3 2 Ajuste de los parámetros La tecla de la primera década permite seleccionar la función elegida dentro de los parámetros p e Adi Sus y la de la sexta década selecciona el siguiente parámetro Des...

Page 4: ...nte cerrado Mínima corriente de conmutación 10 mA Máxima corriente de conmutación 30 VDC 2 A 230 VAC 0 5 A Tiempo de respuesta de la salida 20 ms Inmunidad al ruido A VDE 843 Parte 4 Severidad 3 Temperatura ambiente 10 50 C Temperatura de almacenamiento 20 60 C Peso 80 g Índice de Proteccón IP65 desde delante Color negro Las siguientes medidas pueden ser precisas Si la salida del contador actúa so...

Page 5: ...s 3 touches à lʼatteinte de 0 permet lʼaccés au premier paramètre 3 2 Réglage des paramètres Le choix des différentes possibilités sʼeffectue au moyen de la touche de réglage des unités par exemple additionnant soustrayant tandis que la touche 6 permet lʼaccès au paramètre suivant Après le réglage du dernier paramètre dP la programmation repart au début Ce mode de programmation nʼest abandonné quʼ...

Page 6: ...iel programmable en ouverture ou enfermeture courant minimal 10 mA courant maximal 30 VDC 2 A 230 VAC 0 5 A Temps de réponse de la sortie 20 ms Immunité au bruit jusquʼà VDE 843 Partie 4 Sévérité 3 Température de service 10 50 C Température de stockage 20 60 C Poids 80 g Protection IP65 par lʼavant Teinte du boîtier noir Mesure dʼantiparasitages Les mesures dʼantiparasitages suivantes peuvent sʼav...

Page 7: ... losgelassen dann ist die Parametereinstellung aktiviert und der erste Parameter wird auf dem Display angezeigt 3 2 Einstellung der Parameter Mit der Taste der 1 Dekade wird zwischen den verfügbaren Parametern umgeschaltet z B add sub und mit der Taste der 6 Dekade wird in die nächste Funktion umgeschaltet Nach der letzten Eingabe dP wird an den Anfang der Programmierroutine gesprungen Diese wird ...

Page 8: ...en Typ 1 2AA Lithium 3 6 V Ausgang Bistabiles Relais mit potentialfreiem Kontakt als Schließer oder Öffner programmierbar min Schaltstrom 10 mA max Schaltleistung 30 VDC 2 A 230 VAC 0 5 A Ansprechzeit des Ausganges 20 ms Umgebungstemperatur 10 50 C Lagertemperatur 20 60 C Gewicht 80 g Schutzart IP65 von vorne Farbe schwarz Werkseitige Programmierung Zählweise addierend autom Wiederholung keine Aus...

Reviews: