Insert paper roll

Raise the printer lid as illustrated. Use paper rolls with a width of 57mm and maximum diameter of 70mm. Do not use

recycled paper. This causes quicker printer wear. Prepare the paper roll for insertion. Remove the first layer and cut the

end of the roll straight. This prevents paper jamming in the printer mechanism. Insert the cut end of the roll in the printer

and press 

A

 until approx. 10 cm has been fed in. Depending on the method of use, feed the paper past the tear-off

edge on the printer lid or onto the take-up reel. Finally, close the printer lid.

CM

 18

10

OL

YMPIA

Paper reel

The paper reel is required when the journal paper (special two-layered paper roll with carbon copy facility is required) or

the receipt paper should be rolled onto it.

1.

 

Open the printer lid.

2.

 

Remove the paper reel.

3.

 

Thread the end of the journal paper in the slit in the paper reel.

4.

 

Insert the paper reel in the hollows provided for it.

5.

 

In order to remove the journal paper after it has been rolled up on the reel, remove
the paper reel and pull the journal paper roll off.

6.

 

Reinsert the paper reel.

7.

 

Close the printer lid.

Change ribbon

Note: Only use black/red ribbons. The black side must be at the top.

1. Open the printer lid.

2. Lift the left and right ribbon spools up and out of the guides.

3. Insert new ribbon rolls on the guides.

4. Insert the new ribbon cassette in the printer so that the ribbon is positioned between

the digit roll and paper. The outer edge must rest on the side ribbon guides. Tighten

the ribbon a little.

5. Insert the paper roll.

6. Close the printer lid.

Key-operated switch

The key must be set to position REG for normal operation (registration).

Off

Registration

(normal operation)

X-reports (without

memory deletion)

Z-reports (with

memory deletion)

Programming

Training

Note: Loss of data and jamming of the cash register are possible in operating of Z or P modes! Only use these
modes when you are familiar with programming and operating the machine.

Summary of Contents for CM 1810 plus

Page 1: ...ed onto it 1 Open the printer lid 2 Remove the paper reel 3 Thread the end of the journal paper in the slit in the paper reel 4 Insert the paper reel in the hollows provided for it 5 In order to remove the journal paper after it has been rolled up on the reel remove the paper reel and pull the journal paper roll off 6 Reinsert the paper reel 7 Close the printer lid Change ribbon Note Only use blac...

Page 2: ...ng e g P Amount Print receipt N PPPPPPPP e g P Cancellations Incorrect registrations can be cancelled right after entry or several entries later Direct cancellation The amount last entered can be cancelled during a registration G Entry is cancelled Cancellation indirectly Void Amounts item prices and departments entered incorrectly during a registration can be cancelled later D Activate the Void f...

Page 3: ...amount from credit card X in the drawer x TL Total amount from credit card X in the drawer TS Taxable sales total x CH Total payments with credit cards 1 9 x CA Total amount of currency x in the drawer x CA Total amount of currency x in the drawer CA Number of refunded items TI TII Tax total for taxes 1 2 Taxable at tax 1 2 TIX TIIZ Tax total for taxes 3 4 Taxable at tax 3 4 Registration mode Θ Di...

Page 4: ...ommended setting 0 Machine no Receipt no Clerk Date Time 1 Date Time 2 Machine no Receipt no Clerk Time 3 Time 4 Machine no Receipt no Clerk Date 5 Date 6 Machine no Receipt no Clerk 7 No header FLAG 05 Representation of Z reports 0 Recommended setting Reset receipt no after Z report 0 All report information is printed 1 Grand Total is not printed 2 Consec Z report no is not printed 3 Grand Total ...

Page 5: ...to 9999 FLAG 32 Password for programming 0 0 0 0 No password Password 0001 to 9999 FLAG 33 Password for EC Void NS Refund and PO keys 0 0 0 0 No password Password 0001 to 9999 FLAG 34 Highest acceptable check amount compulsory entry 0 4 0 0 0 0 Example for 400 00 Enter the amount without a decimal point FLAG 35 Fixed tender lower cash tender key 0 0 0 5 0 0 Example for 5 00 a 4 digit number withou...

Page 6: ...x total no net amount 0 Taxes are indicated separately 1 Taxes are added FLAG 47 Short Long reports 1 Recommended setting 0 Only print registered data in X Z 1 Print all data in X Z FLAG 48 Item counter on receipt 1 Recommended setting 0 Item counter printing on receipt activated 1 Item counter printing on receipt deactivated FLAG 49 result registration in department 0 Recommended setting 0 result...

Page 7: ...e input Store the assignment and move to next department Close the department program Programming the Coupon key U E g 1000 N E g 810106 N P Open the coupon program Enter the fixed price Store the fixed price Enter the assignment 8 price will be substracted 1 tax rate 1 01 major group 01 0 itemized receipt 6 maximum number of digits for price input Store the assignment and move to next department ...

Page 8: ...git conversion factor 2 decimal point for the currency DEM N Move to the next setting 052195583 Define the conversion factor for cash payments in DEM and Euro table three way currency conversion FCE 3 0 compulsory entry 5 decimal places of the six digit conversion factor 2 decimal point for the currency DEM N Move to the next setting 042403399 Define the conversion factor for the first foreign cur...

Page 9: ... The grand total entered is stored Set Z report counter 1 max 4 digits P The value entered for the Z report counter is stored Error messages operation Error messages appear in the display and an acoustic signal is issued as a result of incorrect operation J Error message is cleared Error message Cause E00 Incorrect key pressed E01 Incorrect key operation sequence E02 Manually entered PLU is incorr...

Page 10: ...Quick Reference CM 1810 plus plus plus plus Cash Register 13 Olympia 08 2002 Page 10 Rights to make technical changes reserved ...