Clearing errors

Incorrect input or error status (acoustic signal) can be cleared by pressing the 

J

 key.

Registration according to department

Enter price without decimal point (max. 8 digits).

Price

Department

PPPPPPPP

!

Or: if the same item should be registered several times:

No. of items

Price

Department

NNNN

K

PPPPPPPP

!

The sum of NNNN x PPPPPPPP is limited to the maximum capacity of the cash register.

Registration according to item number

Enter item number (3 digits).

Item number

PLU

e.g. 

012

F

Or: if the same item should be registered several times:

No. of items

Item number

PLU

NNNN

K

e.g. 

012

F

The sum of NNNN x item price is limited to the maximum capacity of the cash register.

Print receipt

When all the items have been registered, press the 

N

 key to display the sub-total. Enter the amount paid without

decimal point and print the receipt by pressing e.g. 

P

.

Amount

Print receipt

N

PPPPPPPP

e.g. 

P

Cancellations

Incorrect registrations can be cancelled right after entry or several entries later.
Direct cancellation: The amount last entered can be cancelled during a registration.

G

Entry is cancelled

Cancellation, indirectly (Void): Amounts, item prices and departments entered incorrectly during a registration can be
cancelled later.

D

Activate the Void function

Enter the registration to be cancelled.

Refund / Returned goods: Amounts, item numbers and department prices can be reverted for the registrations for
which payment has been completed in respect of returned items and refunds.

E

Refund function is activated Enter the registration to be reverted,

e.g. 

O

Other functions

L

Cash register is opened. / Printing a maximally 10-digit receipt number.

C

For payments out, enter the amount and press this key.

B

For payments in, enter the amount, press this key to conclude and print the receipt by pressing

P

 or 

O

.

M

Enables the selection of departments 11 to 20 when this function is activated.

H

Following a registration or generating the sub-total, a percentage premium can be entered.

Example: entry for 10%:  

10

H

.

I

Example: entry for 5%:  

5

I

.

Summary of Contents for CM 1810 plus

Page 1: ...ed onto it 1 Open the printer lid 2 Remove the paper reel 3 Thread the end of the journal paper in the slit in the paper reel 4 Insert the paper reel in the hollows provided for it 5 In order to remove the journal paper after it has been rolled up on the reel remove the paper reel and pull the journal paper roll off 6 Reinsert the paper reel 7 Close the printer lid Change ribbon Note Only use blac...

Page 2: ...ng e g P Amount Print receipt N PPPPPPPP e g P Cancellations Incorrect registrations can be cancelled right after entry or several entries later Direct cancellation The amount last entered can be cancelled during a registration G Entry is cancelled Cancellation indirectly Void Amounts item prices and departments entered incorrectly during a registration can be cancelled later D Activate the Void f...

Page 3: ...amount from credit card X in the drawer x TL Total amount from credit card X in the drawer TS Taxable sales total x CH Total payments with credit cards 1 9 x CA Total amount of currency x in the drawer x CA Total amount of currency x in the drawer CA Number of refunded items TI TII Tax total for taxes 1 2 Taxable at tax 1 2 TIX TIIZ Tax total for taxes 3 4 Taxable at tax 3 4 Registration mode Θ Di...

Page 4: ...ommended setting 0 Machine no Receipt no Clerk Date Time 1 Date Time 2 Machine no Receipt no Clerk Time 3 Time 4 Machine no Receipt no Clerk Date 5 Date 6 Machine no Receipt no Clerk 7 No header FLAG 05 Representation of Z reports 0 Recommended setting Reset receipt no after Z report 0 All report information is printed 1 Grand Total is not printed 2 Consec Z report no is not printed 3 Grand Total ...

Page 5: ...to 9999 FLAG 32 Password for programming 0 0 0 0 No password Password 0001 to 9999 FLAG 33 Password for EC Void NS Refund and PO keys 0 0 0 0 No password Password 0001 to 9999 FLAG 34 Highest acceptable check amount compulsory entry 0 4 0 0 0 0 Example for 400 00 Enter the amount without a decimal point FLAG 35 Fixed tender lower cash tender key 0 0 0 5 0 0 Example for 5 00 a 4 digit number withou...

Page 6: ...x total no net amount 0 Taxes are indicated separately 1 Taxes are added FLAG 47 Short Long reports 1 Recommended setting 0 Only print registered data in X Z 1 Print all data in X Z FLAG 48 Item counter on receipt 1 Recommended setting 0 Item counter printing on receipt activated 1 Item counter printing on receipt deactivated FLAG 49 result registration in department 0 Recommended setting 0 result...

Page 7: ...e input Store the assignment and move to next department Close the department program Programming the Coupon key U E g 1000 N E g 810106 N P Open the coupon program Enter the fixed price Store the fixed price Enter the assignment 8 price will be substracted 1 tax rate 1 01 major group 01 0 itemized receipt 6 maximum number of digits for price input Store the assignment and move to next department ...

Page 8: ...git conversion factor 2 decimal point for the currency DEM N Move to the next setting 052195583 Define the conversion factor for cash payments in DEM and Euro table three way currency conversion FCE 3 0 compulsory entry 5 decimal places of the six digit conversion factor 2 decimal point for the currency DEM N Move to the next setting 042403399 Define the conversion factor for the first foreign cur...

Page 9: ... The grand total entered is stored Set Z report counter 1 max 4 digits P The value entered for the Z report counter is stored Error messages operation Error messages appear in the display and an acoustic signal is issued as a result of incorrect operation J Error message is cleared Error message Cause E00 Incorrect key pressed E01 Incorrect key operation sequence E02 Manually entered PLU is incorr...

Page 10: ...Quick Reference CM 1810 plus plus plus plus Cash Register 13 Olympia 08 2002 Page 10 Rights to make technical changes reserved ...

Reviews: