FLAG 28 Duplicate receipt - Printer on/off - Rounding

3 0 0 = Recommended setting
0

= No dup. receipt; no compulsory clerk log-in;

no percentage  display in report

1

= Duplicate receipt; no compulsory clerk log-in;

no percentage display in report

2

= No dup.; no compulsory clerk log-in;

percentage  display in report

3

= Duplicate receipt; no compulsory clerk log-in;

percentage display in report

4

= No dup. receipt; compulsory clerk log-in;

no percentage display in report

5

= Duplicate receipt; compulsory clerk log-in;

no percentage display in report

6

= No dup. receipt; compulsory clerk log-in;

percentage display in report

7

= Duplicate receipt; compulsory clerk log-in;

percentage display in report

0

= Printer on, unit price display

1

= Printer off, unit price display

2

= Printer on, unit price display for

0.5 sec., then total amount

3

= Printer off, unit price display for

0.5 sec., then total amount

0 = Standard rounding 5/4
1 = Scandinavian rounding

(0-0.24=0.00; 0.25-0.74=0.50; 0.75-1=1.00)

2 = Swiss rounding

(0,1,2 = 0; 3,4,5,6,7 = 5; 8,9 = 10)

3   = Danish rounding (0-0,12=0.00; 0.13-

0.37=0.25; 0.38-0.62=0.50; 0.63-0.87=0.75;
0.88-1.12=1.00)

FLAG 29
Password for X-report

0 0 0 0 = No password / Password 0001 to 9999

FLAG 30
Password for Z-report

0 0 0 0 = No password / Password 0001 to 9999

FLAG 31
Password for monthly (periodical) report

0 0 0 0 = No password / Password 0001 to 9999

FLAG 32
Password for programming

0 0 0 0 = No password / Password 0001 to 9999

FLAG 33
Password for EC/Void, NS/#, Refund and PO keys

0 0 0 0 = No password / Password 0001 to 9999

FLAG 34
Highest acceptable check amount - compulsory entry

0 4 0 0 0 0 = Example for £400.00.

Enter the amount without a decimal
point

FLAG 35
Fixed tender (lower cash tender key)

0 0 0 5 0 0 = Example for £5.00;

a 4-digit number without decimal point

FLAG 36
Fixed tender (cash tender key)

0 0 1 0 0 0 = Example for £10.00;

a 4-digit number without decimal point

FLAG 37
Fixed tender (cash tender key)

0 0 2 0 0 0 = Example for £20.00;

a 4-digit number without decimal point

FLAG 38
Fixed tender (upper cash tender key)

0 0 5 0 0 0 = Example for £50.00;

a 4-digit number without decimal point

FLAG 39 Euro conversion activated/deactivated

1 1 1 1 1 0 = Recommended setting
0

= Bottom cash tender key

1

=

 FCE1 key

0

= Second cash tender key from bottom

1

=

 FCE2 key

0

= Second cash tender key from top

1

=

 FCE3 key

0

= Top cash tender key

1

=

 FCE4-9 key

0

= Euro course is not printed

1

= Euro course is printed

0 = Exchange rate is not printed
1 = Exchange rate is printed

Activate FCE or Cash Tender key

Euro conversion
Euro in the period 01.01.1999-31.12.2001
FLAG 39 = 11111x (x = 0 or 1); FLAG 59 = 0
When programming the basic exchange rate, enter yy2xxxxxx,
e.g.:

Euro in the period 01.01.2002-28.02.2002
FLAG 39 = 11110x (x = 0 or 1); FLAG 59 = 1
When programming the basic exchange rate, enter yy2xxxxxx,
e.g.:

Foreign Currency Exchange rates (FCE)
FLAG 39 = 11110x (x = 0 or 1); FLAG 59 = 0
When programming the basic exchange rate, enter yy2xxxxxx if
the normal exchange rate is to be used. E.g.:

I   05

2

195583

I   05

2222

195583

I   05

2

178562

Summary of Contents for CM 1810 plus

Page 1: ...ed onto it 1 Open the printer lid 2 Remove the paper reel 3 Thread the end of the journal paper in the slit in the paper reel 4 Insert the paper reel in the hollows provided for it 5 In order to remove the journal paper after it has been rolled up on the reel remove the paper reel and pull the journal paper roll off 6 Reinsert the paper reel 7 Close the printer lid Change ribbon Note Only use blac...

Page 2: ...ng e g P Amount Print receipt N PPPPPPPP e g P Cancellations Incorrect registrations can be cancelled right after entry or several entries later Direct cancellation The amount last entered can be cancelled during a registration G Entry is cancelled Cancellation indirectly Void Amounts item prices and departments entered incorrectly during a registration can be cancelled later D Activate the Void f...

Page 3: ...amount from credit card X in the drawer x TL Total amount from credit card X in the drawer TS Taxable sales total x CH Total payments with credit cards 1 9 x CA Total amount of currency x in the drawer x CA Total amount of currency x in the drawer CA Number of refunded items TI TII Tax total for taxes 1 2 Taxable at tax 1 2 TIX TIIZ Tax total for taxes 3 4 Taxable at tax 3 4 Registration mode Θ Di...

Page 4: ...ommended setting 0 Machine no Receipt no Clerk Date Time 1 Date Time 2 Machine no Receipt no Clerk Time 3 Time 4 Machine no Receipt no Clerk Date 5 Date 6 Machine no Receipt no Clerk 7 No header FLAG 05 Representation of Z reports 0 Recommended setting Reset receipt no after Z report 0 All report information is printed 1 Grand Total is not printed 2 Consec Z report no is not printed 3 Grand Total ...

Page 5: ...to 9999 FLAG 32 Password for programming 0 0 0 0 No password Password 0001 to 9999 FLAG 33 Password for EC Void NS Refund and PO keys 0 0 0 0 No password Password 0001 to 9999 FLAG 34 Highest acceptable check amount compulsory entry 0 4 0 0 0 0 Example for 400 00 Enter the amount without a decimal point FLAG 35 Fixed tender lower cash tender key 0 0 0 5 0 0 Example for 5 00 a 4 digit number withou...

Page 6: ...x total no net amount 0 Taxes are indicated separately 1 Taxes are added FLAG 47 Short Long reports 1 Recommended setting 0 Only print registered data in X Z 1 Print all data in X Z FLAG 48 Item counter on receipt 1 Recommended setting 0 Item counter printing on receipt activated 1 Item counter printing on receipt deactivated FLAG 49 result registration in department 0 Recommended setting 0 result...

Page 7: ...e input Store the assignment and move to next department Close the department program Programming the Coupon key U E g 1000 N E g 810106 N P Open the coupon program Enter the fixed price Store the fixed price Enter the assignment 8 price will be substracted 1 tax rate 1 01 major group 01 0 itemized receipt 6 maximum number of digits for price input Store the assignment and move to next department ...

Page 8: ...git conversion factor 2 decimal point for the currency DEM N Move to the next setting 052195583 Define the conversion factor for cash payments in DEM and Euro table three way currency conversion FCE 3 0 compulsory entry 5 decimal places of the six digit conversion factor 2 decimal point for the currency DEM N Move to the next setting 042403399 Define the conversion factor for the first foreign cur...

Page 9: ... The grand total entered is stored Set Z report counter 1 max 4 digits P The value entered for the Z report counter is stored Error messages operation Error messages appear in the display and an acoustic signal is issued as a result of incorrect operation J Error message is cleared Error message Cause E00 Incorrect key pressed E01 Incorrect key operation sequence E02 Manually entered PLU is incorr...

Page 10: ...Quick Reference CM 1810 plus plus plus plus Cash Register 13 Olympia 08 2002 Page 10 Rights to make technical changes reserved ...

Reviews: