26 / 88
2019/08
010-296
5
Technical data
5.1
Torques
Description / use
Torque Nm
Spanner size
PT-screw 100x30 A2
7
T50
Fastening clamp / on tank
3
ISK 10mm
Pipe clamp D=120
8-10
Socket 13mm
Pipe clamp D=84
8-10
Socket 13mm
5.2
Pre-conditions / basis for calculation
The parameters for operation (disposal) of the grease separator are based on these values:
– Pumping capacity (extraction capacity) of the disposal vehicle 10 l/s = 36 m³/h.
– Cold / hot water supply 1l/s with DN25,
– Room temperature at least +15° C.