![Kessel Aquapump Small Installation And Operating Manual Download Page 66](http://html1.mh-extra.com/html/kessel/aquapump-small/aquapump-small_installation-and-operating-manual_1957985066.webp)
EN
Establish cable pass-through
Conduit pipe connection (variant A)
The conduit pipe is to be installed with max. 45° bend.
Select drill with appropriate hole saw (Art. no. 500101).
Carry out drilling for the conduit pipe in accordance with
the hole saw instructions.
Insert conduit pipe seal.
Grease conduit pipe and slide through the conduit pipe
seal.
Cables/plugs can be fed through the conduit pipe.
... or
Cable fastener (variant B)
For this connection the mains cable must be cut in
order to pull it through the cable screw connection.
When installed correctly and in accordance to the reg-
ulations for electrical safety the manufacturer’s war-
ranty remains unaffected.
Drill hole for cable fastener (M16).
Insert cable fastener into the chamber, screw into place
and bond with PVC adhesive.
Feed cable through the cable fastener and clamp in
place.
66 / 144
Pumping station / Installation and operating manual
016-102_05
Summary of Contents for Aquapump Small
Page 13: ...3 4 Funktionsprinzip DE 016 102_05_DE_EN_FR Pumpstation Einbau und Bedienungsanleitung 13 144...
Page 59: ...3 4 How it works EN 016 102_05 Pumping station Installation and operating manual 59 144...
Page 140: ......
Page 141: ......
Page 142: ...142 144 016 102_05_DE_EN_FR...
Page 143: ...016 102_05_DE_EN_FR 143 144...