Level sensor Mono/Duo (non-ATEX)
Connect the cable ends of the level sensor to the terminals
(see "Fig. 3: Connecting the level sensor"). The connection
of level sensors is identical for both Mono and Duo systems.
Use KESSEL junction box (art. no. 28799) to lengthen the
connection cable of the level sensor.
Wire colour
Name on PCB
Terminal colour
red
On/ON1
white
black
On/On1
blue
Use KESSEL connection box (art. no. 28799) to lengthen
the connection cable of the level sensor.
Fig. 3: Connecting the level sensor
4.5.1.2 Connecting diaphragm pressure switches
Diaphragm pressure switches for Mono systems
Connect the cable ends of the diaphragm pressure switches
to the terminals (see "Fig. 4: Diaphragm pressure switch
Fig. 4: Diaphragm pressure switch Mono
Wire colour
Name on PCB
Terminal colour
yellow
white
green
Alarm
blue
brown
white
white
ON
blue
EN
010-532_02_SON
Installation and operating instructions
57 / 124