4. Service and maintenance
Fig. 17 Bleeder
Fig. 18 Activated carbon filter
Fig. 19 Cover
Fig. 20 Bayonet locking cap
4.7 How the emergency valve works
Locking position:
The backwater flap is
closed by pressing the TEST key (flap).
The backwater flap works as a pipe bar-
rier. This function is only considered as
protection from backwater during longer
periods of absence (e.g. holidays).
Connected draining points are still drai-
ned.
After return, the emergency valve
must be re-opened again for normal
operation:
by pressing the TEST key
(flap) again.
Make sure that there is no backwater
when this takes place.
4.8 Servicing the ventilation
The ventilation (see spare parts section 6)
must be cleaned regularly and the activa-
ted carbon filter (Fig. 18) must be changed
annually or as required.
The ventilation must be cleaned and
checked after every pump failure.
The bleeder (Fig. 17 from right to left) com-
prises seal, drain body, float ball, seal,
bayonet locking cap, activated carbon fil-
ter and cover.
Pull the cover off (Fig. 19) by tilting it slight-
ly to the side. Then turn bayonet locking
cap (Fig. 20)
➀
and pull it up and off
②
.
Remove seal and float ball and clean
everything. Re-assembly takes place in
reverse order.
➀
➁
Abb. 17
Emergency flap can be locked by hand
20
010-843EN_2013_10_205-054 02/07 -1 15.10.13 11:21 Seite 8
Summary of Contents for 83071
Page 11: ...11 010 843_2013_10_ohne_standard_205 054 02 07 1 15 10 13 09 40 Seite 11...
Page 23: ...23 010 843EN_2013_10_205 054 02 07 1 15 10 13 11 21 Seite 11...
Page 35: ...35 010 843IT_2013_10_205 054 02 07 1 15 10 13 10 10 Seite 11...
Page 47: ...47 010 843FR_2013_10_205 054 02 07 1 15 10 13 10 19 Seite 11...
Page 59: ...59 010 843PL_2013_10_pumpfix 15 10 13 11 04 Seite 11...
Page 71: ...71 010 843NL_2013_10_205 054 02 07 1 15 10 13 11 17 Seite 11...