![Kessel 83071 Instructions For Assembly, Operation And Maintenance Download Page 17](http://html1.mh-extra.com/html/kessel/83071/83071_instructions-for-assembly-operation-and-maintenance_1957974017.webp)
3.4 Installation in an exposed wastewa-
ter pipe
The version for free-standing set-up is deliver-
ed with a protective hood to prevent damage to
the components following commissioning. Fig.
7 shows the cable ducts.
3.5
Installation in groundwater
(Seal set art. no. 83023
If the valve is to be installed in groundwater,
the flange serves as the necessary sealing
level for a white or black tub (see Figure).
For this purpose, seal sheeting is clamped
between the plastic counterflange and the
compression seal flange integrated on the
drain body, and screwed together using the
enclosed screws.
The sheeting used on site can be used as
seal sheeting. For installation in a waterpro-
of white tub, KESSEL also has matching
seal sheeting available made of natural rub-
ber NK/SBR, where the bore holes for the
screws have already been cut out (see Fig. 8).
If it is necessary to perforate the waterproof
concrete tub to connect feed pipes, cable
conduits etc., these holes must also be set
up waterproof. Maximum groundwater resi-
stance is 2 m.
Installation with extension (order no.
83071).
Use of the extension allows the flange
height to be individually adjusted. The
attachment must be shortened to the re-
quired height if necessary.
3.6
Special features of
Pumpfix F
Komfort
Pumpfix F Komfort has an integrated drai-
ning function for surface water drainage.
3.7
Set-up
Connection of the draining function to the
feed cover is via the enclosed draining
connection. Insert the draining connection
into the prescribed opening and lock using
the one-handed quick-action closure.
Depending on installation depth (installati-
on depth of the upper cover section), the
draining connection must be shortened to
the respective length (see Fig. 9) or exten-
ded using HT-pipe DN 70 if recessed in-
stallation using extension (art. no. 83071) is
used.
3. Installation
➀
KESSEL-Pumpfix F, Staufix FKA, Staufix SWA, Controlfix
➁
Compression seal flange with seal set art. no. 83023
➂
Extension art. no. 83071
➃
Adapter DN 100 with compression seal flange made of stainless
steel art. no. 27198
➄
Elastomer sealing sheet art. no. 27159
➅
Upper cover section with plastic cover plate
➆
Control unit
➇
Locking lever
BWS *
Fliesen
Estrich
Dämmung
Betonboden
S
4
5
2
1
*
BWS
Unterbeton
Fliesen
Estrich
Dämmung
Betonboden
Schutzbeton
Abdichtung
4
1
2
3
*
Installation example “white tub”
Installation example “black tub”
WU-Beton
➅
➆
➇
Seal seat (83023)
• Counterflange • Sealing sheet
Fig. 8
Pumpfix F Komfort
Fig 9
Fig. 7
Tiles
Screed
Insulation
Concrete floor
Protective concrete
Sealing
Underfloor
Tiles
Screed
Insulation
Concrete floor
17
010-843EN_2013_10_205-054 02/07 -1 15.10.13 11:20 Seite 5
Summary of Contents for 83071
Page 11: ...11 010 843_2013_10_ohne_standard_205 054 02 07 1 15 10 13 09 40 Seite 11...
Page 23: ...23 010 843EN_2013_10_205 054 02 07 1 15 10 13 11 21 Seite 11...
Page 35: ...35 010 843IT_2013_10_205 054 02 07 1 15 10 13 10 10 Seite 11...
Page 47: ...47 010 843FR_2013_10_205 054 02 07 1 15 10 13 10 19 Seite 11...
Page 59: ...59 010 843PL_2013_10_pumpfix 15 10 13 11 04 Seite 11...
Page 71: ...71 010 843NL_2013_10_205 054 02 07 1 15 10 13 11 17 Seite 11...