benchmarkwireline.com
P. O. BOX 850
Fax: 281.342.4848
Phone: 281.342.6415
Simonton,Texas 77476
36220 FM 1093
June-2007
Rev D
Page 14 of 18
6.8 Depth
measurement
Quadrature counts/revolution
16
Measurement resolution
0.048 m
0.1573 ft
Display resolution
0.1 m
0.1 ft
6.9 Line
Speed
Minimum Line Speed
0 ft/min
Maximum Line Speed
1200 ft/min
6.10 Power
management
Power time-out with idle
magnetic pickup
60 min
The battery voltage and charge current can be displayed by pressing
enable and menu at the same time.
The voltage will be displayed as:
E 4180
4180 would be a battery voltage of 4.18 volts. When the battery
reaches 4.8v the charge will stop.
The charge current will be displayed as:
A 310
310 would be a battery charge current of 310 ma.
The display will cycle between the voltage and current display as long
as the buttons are being depressed.
The charge current is limited to between 250 ma and 350 ma.