42
•
The connection to the main must be made using an earthed plug or via an omnipolar circuit breaking
device with a contact opening of at least 3 mm.
•
The electrical circuit must be separated from the network by adapted devices, for example: circuit
breakers, fuses or contactors.
•
If the appliance is not fitted with an accessible plug, disconnecting means must be incorporated in the
fixed installation, in accordance with the installation regulations.
•
The inlet hose must be positioned so that it does not touch any of the hot parts of the hob or even.
CAUTION:
•
This appliance must only be connected to a network 230 V~ 50/60 Hz.
•
Always connect the earth wire.
•
Respect the connection diagram.
•
The connection box is located underneath at the back of the hob casing. To open the cover, use
a medium screwdriver. Place it in the slits and open the cover.
MAINS
CONNECTION
CABLE DIAMETER
CABLE
PROTECTION
CALIBRE
230V~ 50/60Hz
1 Phase + N
3 x 2,5 mm²
H 05 VV - F
H 05 RR - F
25 A *
400V~ 50/60Hz
2 N
4 x 1,5 mm²
H 05 VV - F
H 05 RR - F
16 A *
* calculated with the simultaneous factor following the standard EN 60 335-2-6
CONNECTION OF THE HOB
For the various kinds of connection, use the brass bridges which are in the box next the terminal
Monophase 230V~1P+N
Put the 1st bridge between terminal L1 and L2, the 2nd between N1 and N2.
Attach the earth to the terminal “earth”, the neutral N to terminals N1 or N2, the Phase
L to one of the terminals L1 or L2.
Biphase 400V~2P+N
Put the bridge between terminal N1 and N2.
Attach the earth to the terminal “earth”, the neutral N to terminal N1 or N2, the Phase L1 to the terminal L1
and the Phase L2 to the terminal L2.
CAUTION:
Be careful that the cables are correctly engaged and tightened
.
WE CANNOT BE HELD RESPONSIBLE FOR ANY INCIDENT RESULTING FROM
INCORRECT CONNECTION OR WHICH COULD ARISE FROM THE USE OF AN
APPLIANCE WHICH HAS NOT BEEN EARTHED OR HAS BEEN EQUIPPED
WITH A FAULTY EARTH CONNECTION.
Summary of Contents for KIH 7432-2B
Page 1: ...1 INSTRUKCJA MONTA U ORAZ OBS UGI P YTY GRZEWCZEJ KIH 7432 2B...
Page 2: ...2...
Page 22: ...22 INSTRUCTIONS FOR USE AND INSTALLATION OF KITCHEN HOB KIH 7432 2B...
Page 23: ...23...
Page 43: ...43 N VOD K MONT I A OBSLUZE VARN DESKY KIH 7432 2B...
Page 44: ...44...
Page 64: ...64 KIH 7432 2B...
Page 65: ...65...
Page 67: ...67 1...
Page 68: ...68 2...
Page 69: ...69...
Page 71: ...71 Booster Stop Go SLIDER ON OFF 3 Keep Warm Stop Go ON OFF...
Page 72: ...72 4 0 1 9 U E H P Booster Booster Brigde Bridge L U Keep Warm 70 C II Stop Go...
Page 73: ...73 5 SLIDER SLIDER Slider SLIDER...
Page 77: ...77 CL 00 SLIDER 9 0 9 09 0 9 SLIDER 2 2 9 29 29 00 00 On Off 0 H P i 0 0 L L 5 P i L P 0 H 29...
Page 78: ...78 6 9 1 2 2 3 3 4 4 5 6 7 7 8 9 P...
Page 79: ...79 7 U E L U Keep warm II Stop Go...
Page 81: ...81 E6 E8 E C E 4 U400...
Page 82: ...82 8 2 3 KIH 7432 2B 750 490 50 Y 100 C 20 760...
Page 84: ...84 www kernau com...