SECTION 1 - DESCRIPTION

1.1

GENERAL

The Kepco Model RA 55 Rack Adapter (Figure 1) is designed for the installation of Kepco MST
Series Power Supplies into a standard 19-inch rack. Each rack adapter can accommodate a
maximum of nine power supplies, or eight power supplies and a communication bus controller
(Kepco Model MST 488-27) installed in slot 9. The RA 55 has a removable plate at the rear of
slot 9 to allow for the controller connector.

FIGURE 1.    KEPCO MODEL RA 55 RACK ADAPTER

1.2

ELECTRICAL

The rack adapter contains a PCB backplane whose connectors facilitate hot-swapability. Dual
a-c input terminal blocks (J10 and J11) on the backplate assembly (Figure 2) distribute input
power to nine PCB-mounted a-c input/control bus power connectors (P1 - P9) as shown in
Figure 4. Terminal block J10 provides input power slots 1 through 4; terminal block J11 pro-
vides input power to slots 5 through 9 Two-wire IEEE 1118 control bus data is supplied to the
nine a-c input/control bus power supply connectors via two 9-pin (six pins are not used) con-
nectors, J12 and J13 on the backplate assembly. The utilized pins of the two IEEE 1118 con-
trol bus connectors are paralleled, facilitating "daisy chain" control bus configurations. A
shield connection is routed to connector P9 for grounding within the controller when a control-
ler is installed; otherwise this connection is not used. 

Summary of Contents for RA55

Page 1: ...ion Office in New York 718 461 7000 requesting the correct revision for your par ticular model and serial number 3 The contents of this manual are protected by copyright Reproduction of any part can b...

Page 2: ...355 USA Importer s Name and Address Type of Equipment Rack Adapter Model No PRODUCT MODEL NUMBER Year of Manufacture I the undersigned declare that the product specified above when used in conjunction...

Page 3: ...wire power systems This equipment must be installed within a suitably wired equipment rack utilizing a three wire grounded mains connection See wiring section of this manual for complete electrical w...

Page 4: ...product s rear panel To reconfigure the product input for other nominal mains voltages as listed herein the product must be modified by a trained service technician The PROTECTIVE EARTHING CONDUCTOR T...

Page 5: ...ADAPTER 2 1 Input Power 6 2 1 1 General 6 2 1 2 Safety Grounding 6 2 1 3 Source Power Connections 6 2 2 Load Connections 7 2 3 Control Signal Connections 7 2 4 Slot 9 Configuration 7 1 Kepco Model RA...

Page 6: ......

Page 7: ...lity Dual a c input terminal blocks J10 and J11 on the backplate assembly Figure 2 distribute input power to nine PCB mounted a c input control bus power connectors P1 P9 as shown in Figure 4 Terminal...

Page 8: ...their operating temperature range by means of internal cooling fans ALL INLET AND EXHAUST OPENINGS AT THE TOP BOTTOM AND REAR OF THE RACK ADAPTER CASE MUST BE KEPT CLEAR OF OBSTRUCTION TO ENSURE PROPE...

Page 9: ...B connector Kepco P N 142 0225 one 5 pin DIN connector Kepco P N 142 0308 Kepco 118 0749 Not supplied Cable BIT bus 2m long two 5 pin DIN connectors Kepco P N 142 0308 Kepco 118 0699 Not supplied Term...

Page 10: ...4 RA55 032615 FIGURE 4 RA 55 INTERCONNECTIONS AND INPUT OUTPUT PIN CONNECTIONS...

Page 11: ...RA55 032615 5 FIGURE 5 MECHANICAL OUTLINE DRAWING OF THE RA 55 RACK ADAPTER...

Page 12: ...rules are described in detail in the following paragraphs All interconnections are accomplished at the backplate assembly Figure 2 Refer to Figure 3 for RA 55 interconnections and input output connec...

Page 13: ...00V rms can result in source current in excess of 15A at terminal block J10 or J11 For this reason Kepco rec ommends use of 14 AWG wire minimum in fully populated systems For lower system power config...

Page 14: ...efore installing MST Power Module in RA 55 Rack Adapter pull out the two captive thumb screws at the front of the Power Module and turn counterclockwise until the threads engage FIGURE 6 LOAD CONNECTO...

Reviews: