background image

GE Digital Energy 

Power Quality 

 
 
 
 
 
 

 

 

 

 

 
 
 
 
 

Installation Guide 

 

Digital Energy™ 

SNMP / WEB ADAPTER 

P/N 1018959  3-ph SNMP/Web plug-in adapter 
P/N 1019070  1-ph SNMP/Web plug-in adapter 

P/N 23954  SP SNMP/Web plug-in adapter 

P/N 1019071  1-ph SNMP/Web external adapter 

 
 
 
 
 

GE Consumer & Industrial SA

 

General Electric Company 
CH – 6595 Riazzino (Locarno) 
Switzerland 
T +41 (0)91 / 850 51 51 
F +41 (0)91 / 850 51 44 

 

www.gedigitalenergy.com 
 
 
 
 
 

     

 

 

GE imagination at work 

 

Summary of Contents for Digital Energy 1018959

Page 1: ...lug in adapter P N 1019070 1 ph SNMP Web plug in adapter P N 23954 SP SNMP Web plug in adapter P N 1019071 1 ph SNMP Web external adapter GE Consumer Industrial SA General Electric Company CH 6595 Riazzino Locarno Switzerland T 41 0 91 850 51 51 F 41 0 91 850 51 44 www gedigitalenergy com GE imagination at work ...

Page 2: ...MP Web plug in adapters 13 05 2008 COPYRIGHT 2008 by GE Consumer Industrial SA All rights reserved The information contained in this publication is intended solely for the purposes indicated The present publication and any other documentation supplied with the UPS system is not to be reproduced either in part or in its entirety without the prior written consent of GE The illustrations and plans de...

Page 3: ...he highest standards of quality will give you complete satisfaction Please read carefully the Installation Manual which contains all the necessary information about the installation of the adapters Thank you for choosing GE Distributed by Your service contact g GE Digital Energy General Electric Company CH 6595 Riazzino Locarno Switzerland Modifications reserved Page 3 24 ISG_CNT_SNM_BAS_CRD_1GB_V...

Page 4: ... 1019070 16 3 3 SP SNMP WEB PLUG IN ADAPTER P N 1019070 17 3 4 1 PH SNMP WEB EXTERNAL ADAPTER P N 1019071 17 3 5 INTERFACES 18 4 CONFIGURATION 19 4 1 CONFIGURATION METHODS 19 4 1 1 Configuration via serial connection 19 4 1 2 20 Configuration via the network 4 2 21 NETWORK PARAMETERS 4 2 1 Default configuration 21 4 2 2 Reboot 21 4 3 21 FURTHER INFORMATION 5 22 ACCESS 5 1 22 WEB INTERFACE 5 2 22 T...

Page 5: ... should be performed by qualified service personnel only The KNOWLEDGE of and FULL compliance to the safety instructions and the warning contained in this manual are THE ONLY CONDITION to avoid any dangerous situations during installation operation maintenance work and to preserve the maximum reliability of the UPS system NOTE While every care has been taken to ensure the completeness and accuracy...

Page 6: ... protection e g wrist straps The SNMP Web adapters contain a removable lithium coin cell battery Perchlorate Material special handling may apply See www dtsc ca gov hazardouswaste perchlorate INSTALLATION Switching OFF the unit does not isolate the UPS from the mains Do not install the equipment in an excessively humid environment or near water Avoid spilling liquids on or dropping any foreign obj...

Page 7: ...ons WARNING The UPS contains hazardous voltages Observe carefully the safety instructions to prevent risk of electrical shock CAUTION The SNMP Web adapter contains a lithium coin cell battery RISK OF EXPLOSION IF BATTERY IS REPLACED BY AN INCORRECT TYPE DISPOSE OF USED BATTERIES ACCORDING TO THE INSTRUCTIONS Perchlorate Material special handling may apply See www dtsc ca gov hazardouswaste perchlo...

Page 8: ...iver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help 3 ph SNMP Web plug in adapter P N 1018959 SP SNMP Web plug in adapter P N 23954 These devices have been tested for compliance with the following standards EN 61000 6 2 EN 61000 6 4 WARNING This is a Class A product In a dome...

Page 9: ...tes for old SitePro UPS ref Appendix A Front panel for LP33 Series UPSs 1 ph SNMP Web plug in adapter P N 1019070 SP SNMP Web plug in adapter P N 23954 1 ph SNMP Web plug in adapter Installation manual Third Party License ReadMe CD ROM SP SNMP Web plug in adapter P N 23954 SP SNMP Web plug in adapter Installation manual Third Party License ReadMe CD ROM 1 ph SNMP Web external adapter P N 1019071 1...

Page 10: ...Active LAN UPS 4 3 2 1 1 2 3 4 1 RJ45 Connector Ethernet connection 10Base T or 100Base TX 2 LEDs Ref specific section 3 RS 232 port Local console connection 115200 N 8 1 4 Reset button HW reset 1 ph SNMP Web plug in adapter P N 1019070 Reset RS 232 UTP 10 100 Active LAN Contact interface UPS Reset RS 232 UTP 10 100 Active LAN Contact interface UPS Front Panel User Interface View 5 4 3 2 1 Modific...

Page 11: ...0 N 8 1 4 Reset button HW reset 1 ph SNMP Web external adapter P N 1019071 1 RJ45 Connector Ethernet connection 10Base T or 100Base TX 2 LEDs Ref specific section 3 RS 232 port Local console connection 115200 N 8 1 4 Reset button HW reset 6 Power in AC adapter connection 7 UPS port RS 232 connection to the UPS Net link Fault Active reset Front View 2 4 3 1 6 7 Rear View Reset RS 232 UTP 10 100 Act...

Page 12: ...ction speed Use of DHCP BOOTP or manual configuration for the TCP IP network settings SNMP Agent Web server Console interface UPS status alarms readings event logging over different interfaces Digital outputs open collector outputs for relay drive 1 ph plug in version only SNMP Traps and E mail notification upon UPS event Advanced security features 2 4 ARCHITECTURE ARCHITECTURE DIAGRAM UPS Windows...

Page 13: ...ROM containing the following documentation Installation Manual Operating Manual SNMP Management Information Base MIB Release notes and other instructions as applicable Modifications reserved Page 13 24 ISG_CNT_SNM_BAS_CRD_1GB_V012 doc Installation Guide SNMP Web Adapter ...

Page 14: ...its produced before 2003 require an additional protective ground connection refer to APPENDIX A 3 1 1 Setting the logical address The logical address is configured through dip switch SW1 in the following way Logical Address Dip 1 Dip 2 SNMP Card 0 1 84 54h ON ON SNMP Card 1 85 55h ON OFF SNMP Card 2 86 56h OFF ON SNMP Card 3 87 57h OFF OFF 1 Default setup Dip switch SW1 NOTE The logical address is...

Page 15: ...covers the Option slot by cutting the edges which are holding the plate Take care the plate does not fall inside the UPS 2 Slide carefully the SNMP adapter into the Options slot 3 Fix the front plate of the SNMP adapter to the UPS using the screw included in the SNMP Web adapter kit Install procedure for SitePro S6 Q2 Q1 Q4 1 Change the front plate with the smaller one delivered with the Kit 2 Ins...

Page 16: ...ow the UPS may be switched on or back to normal mode from manual bypass 3 2 1 PH SNMP WEB PLUG IN ADAPTER P N 1019070 Switch off the UPS and wait approx 2 minutes or switch the UPS to the manual bypass In the latter case please ensure that the mains input is reliable during this period Install the SNMP WEB Interface card in the RS232 option slot For more details about the slot please read the UPS ...

Page 17: ...lot please read the UPS user manual Make all necessary connections see architecture diagram in section 2 4 Switch on the UPS or go back to normal mode from bypass 3 4 1 PH SNMP WEB EXTERNAL ADAPTER P N 1019071 Connect the network cable to the box Connect the UPS to the SNMP WEB Interface box Sub D connector UPS using the cable provided with the UPS VIC 23 or IMV I or 1 1 straight cable for intelli...

Page 18: ... 3 5 4 1 6 7 8 9 TD RD 2 3 5 4 1 6 7 8 9 TD RD Connector pin out as follows Pin Function 2 TD Transmit Data 3 RD Receive Data 5 GND Contact interface RJ11 port 1 ph plug in version only Plug in contact interface port Connector pin out as follows Pin Function 1 Mains failure 2 General alarm 3 Battery low 4 On bypass 5 N C 6 GND Active if the output voltage of the UPS is no longer guaranteed due to ...

Page 19: ... HyperTerminal on a PC running Windows Configure the terminal simulator as follows 115 200bps 8 data bits 1 stop bit parity none flow control none Terminal emulation VT 100 Establish the connection and press enter The default username login and password are ge and ge A command line configuration interface is entered Type menu to enter the quick network configuration menu Modifications reserved Pag...

Page 20: ...g S on the quick configuration menu Entering nvsave at the command interface prompt 4 1 2 Configuration via the network TELNET Launch a telnet client e g on a PC running Windows select Run from the Start menu and type telnet IP The default username login and password are ge and ge A command line configuration interface is entered WEB BROWSER Launch a web browser Enter the URL of the SNMP Web adapt...

Page 21: ...ter The factory default configuration for the SNMP Web adapter is using DHCP Assign the IP address to the adapter MAC address in your DHCP server Then reboot the adapter in order to have it retrieve the IP address The adapter is now accessible and configurable over the network 4 2 2 Reboot Every time the network settings are changed these become effective only after a reboot The adapter can be reb...

Page 22: ...rify the adapter installation cabling and network configuration Check the Ethernet connection to the adapter by launching a ping command from a workstation in the same subnet E g in a Windows system Select Run from the Start menu Enter ping IP e g ping 192 168 24 14 Verify that the SNMP Card adapter is correctly replying 5 3 FURTHER INFORMATION For more information and in order to make full use of...

Page 23: ... line support available on request Internet access required 6 3 WWW SERVER We have a WWW server running at www gedigitalenergy com With your favourite web browser you can access the latest information from GE and download updates and manuals for this product Modifications reserved Page 23 24 ISG_CNT_SNM_BAS_CRD_1GB_V012 doc Installation Guide SNMP Web Adapter ...

Page 24: ... square plates delivered with the 3 ph adapter kit must be mounted refer to the pictures below for the installation details Note Should the UPS be already equipped with the plates please ignore this step Square plates Square plates mounting position Square plate mounting detail Plug in adapter earth connection Modifications reserved Page 24 24 ISG_CNT_SNM_BAS_CRD_1GB_V012 doc Installation Guide SN...

Reviews: