III — SPECIFICATIONS (STANDARD) - CONTINUED

HOLDUP TIME:  

37 ms. typ., 20 ms. min. (100V a-c)
45 ms. typ., 25 ms. min. (240V a-c)

DIELECTRIC STRENGTH: 

 

Between input and output: 

2KV a-c for one minute.

Between input and case (ground): 

2KV a-c for one minute.

Between output and case (ground): 

[500V a-c for one minute.]

INSULATION RESISTANCE: 

 Between input and

ground, output and ground, input and output:

100 Megohms min. (500V d-c).

LEAKAGE CURRENT  

0.23mA typical, 0.35 mA maximum

(per IEC 950 and UL1950,120V a-c)

0.45mA typical, 0.70 mA maximum 

(per IEC 950 and UL1950, 240V a-c)

SAFETY:  

Units are designed to meet UL60950 3rd Edi-

tion, CSA 22.2 No. 60950 [60950-1], and EN60950 and are
CE marked per the Low Voltage Directive (LVD), 73/23/
EEC and 93/68/EEC. The standards do not apply with DC
input operation.

EMI:  

Designed to meet FCC Class B (100-120V a-c) and

VDE 0871 Class B (220-240V a-c).

VIBRATION:  

(non-operating, one hour on each one of

the three axes):

5-10 Hz, 10 mm amplitude.
10-55 Hz, 2g acceleration.

SHOCK:  

(non-operating, one-half sinusoidal pulse, three

shocks to each axis):

Acceleration: 60g 
Duration: 11ms +5ms

OPERATING TEMPERATURE:  

See Figure 4.

FIGURE 4.  % OUTPUT POWER RATING VS. 

AMBIENT TEMPERATURE

STORAGE TEMPERATURE:  

-30

o

C to +75

o

C.

RELATIVE HUMIDITY:  

Operating and storage: up to

95% (wet bulb temp. <35

o

C non-condensing).

FUSE:  

Slow Blow, 3.15A, 250V; (5 x 20 mm), 

Littelfuse, P/N 2153.15PF; 
Kepco P/N 541-0135.

DIMENSIONS:  

See Figure 6.

WARRANTY:  

5 years.

Standard models 

(no suffix)

Options 

C, T, X and Y

Summary of Contents for HSF 3.3-20PFC

Page 1: ...ard models and Section IV on page 6 suffix C T X and Y OPTIONS Options are identified by suffix T PFCT offers improved efficiency and less weight C PFCC offers current monitoring via an integral curre...

Page 2: ...se line ac input line failure etc results in an alarm All models include an isolated internal relay offering nor mally closed and normally open contacts referenced to an isolated common These contacts...

Page 3: ...e operating at between 10 to 100 of rated output current If current to the load goes below 10 for each unit in cur rent share mode all MASTER ON lights may go on see load effect specifications this in...

Page 4: ...emperature effects 0 9 typ 1 8 max Time Effect 1 2 hr 8 hr at 25o C 0 2 typ 0 5 max RECOVERY CHARACTERISTICS A step load change from 50 to 100 produces less than 4 output excursion Recovery occurs to...

Page 5: ...c SAFETY Units are designed to meet UL60950 3rd Edi tion CSA 22 2 No 60950 60950 1 and EN60950 and are CE marked per the Low Voltage Directive LVD 73 23 EEC and 93 68 EEC The standards do not apply wi...

Page 6: ...rature effects 0 9 typ 1 8 max Time Effect 1 2 hr 8 hr at 25o C 0 2 typ 0 5 max TABLE 2 OUTPUT RATINGS AND SPECIFICATIONS HSF PFC 100W SERIES SUFFIX C T X Y ONLY MODEL HSF 3 3 25 1 2 7 PFCC PFCT PFCX...

Page 7: ...TION RESISTANCE Between input and ground output and ground input and output 100 Megohms min 500V d c LEAKAGE CURRENT per IEC 950 and UL 1950 0 13mA typ 0 19 mA maximum 120V a c 0 45 mA maximum 240V a...

Page 8: ...TION DO NOT repeatedly toggle the POWER on off switch as this may cause unit to fault When output voltage is available the green VDC ON LED is on While monitoring output voltage at the front panel tes...

Page 9: ...ORD AVENUE FLUSHING NY 11355 U S A TEL 718 461 7000 FAX 718 767 1102 http www kepcopower com email hq kepcopower com 083013 228 1533 REV 15 9 FIGURE 6 HSF PFC 100W INCLUDING SUFFIX C T X AND Y POWER S...

Reviews: