III — SPECIFICATIONS (STANDARD)

The following specifications apply to all standard (no suf-
fix) HSF-PFC 100 Watt Series models. Table 1 lists the
specifications that differ for each model. Common specifi-
cations that apply to all standard models are listed in the
paragraphs following Table 1. Other models are also avail-

able; consult your Kepco representative for their specifica-
tions.

NOTE

:  Common specifications apply to all models except

where otherwise indicated.

INPUT: 

Voltage: 

Nominal:120V a-c/240V a-c; 

Range: 

90-264V a-c; 

125-370V d-c. (polarity insensitive)

Frequency: Nominal: 50-60 Hz; Range: 47-440Hz

(From 66 to 440 Hz leakage current may exceed
UL/VDE safety spec. limit.)

Current (nominal output at rated load):

1.4A a-c max

 

@120V a-c rms

1.2A max for 3.3V model

0.7A a-c max

 

@240V a-c rms 

0.6A max for 3.3V model

Initial Turn-on Surge: cold start 25°C (First surge

only, not including the current flow into the EMI fil-

ter):

14A typ. @ 100 V a-c, 100% load

28A typ. @ 200 Va-c, 100% load

Power Factor: 0.99 typ. @100V a-c;

 0.95 typ. @ 200V a-c.

Switching Frequency:

135KHz typical

STABILIZATION: 

Source Effect (full load): 0.2% typ.; 0.3% max.

Range 90-132V a-c, 170 -264V a-c, 

Load Effect (10% to 100% load change): 

0.5% typ.; 1.5% max.

Temperature Effect: Range –10

o

 to 71

o

0.5% typ.; 1.0% max.

Combined Effect (includes source, load, and 

temperature effects):

0.9% typ.; 1.8% max.

Time Effect (1/2 hr-8 hr at 25

o

C): 

0.2% typ.; 0.5% max.

RECOVERY CHARACTERISTICS:  

A step load

change from 50% to 100% produces less than +4% output
excursion. Recovery occurs to 1% of the original
setting in <1 ms (load change t

or t

f

 equal to or greater

than 50

µ

sec). 

START-UP TIME:  

500 ms. maximum @100V a-c
300 ms. typical @100V a-c 
200 ms. maximum @240V a-c 
100 ms. typical @240V a-c 

TABLE 1.   OUTPUT RATINGS AND SPECIFICATIONS, HSF-PFC 100W SERIES (STANDARD: NO SUFFIX)

MODEL

HSF

 3.3-20PFC

HSF

5-20PFC

HSF

12-8.5PFC

HSF

15-7PFC

HSF

24-4.5PFC

HSF

28-3.8PFC

HSF

 48-2.1PFC

OUTPUT VOLTS, d-c (NOMINAL)

3.3V

5V

12V

15V

24V

28V

48V

ADJUSTMENT RANGE

2.8 - 3.4V

4.3 - 5.3V

11.4 - 12.6V

13.5 - 16.5V

19.2 - 26.0V

26.5 - 29.5V

44.0 - 52.0

OVERVOLTAGE SETTING

 (25 °C, NOM. INPUT)

3.4 - 4.6V

5.2 - 6.0V

13.2 - 15.2V

16.5 - 18.5V

26.5 - 30.0V

31.5 - 34.5

53.0 - 59.5

OUTPUT CURRENT (NOMINAL)

(1)

20A

20A

8.5A

7.0A

4.5A

(6.5A Peak)

(4)

3.8A

2.1A

CURRENT LIMIT

(2)

26.2A min

21.0A min

8.92A min

7.35A min

    6.82A min

3.99A min

2.2A min

OUTPUT POWER (MAX.)

(3)

68W

100W

99.6W

99W

100.8W

98W

96W

EFFICIENCY (typ.)

100 Va-c

74%

77%

80%

80%

81%

81%

83%

240 Va-c

77%

82%

84%

84%

85%

85%

86%

RIPPLE AND NOISE

(5)

(mV p-p)

0-40°C, 10-100% 

LOAD

switching (max)

80

80

100

100

100

100

130

spike noise (max)

(d-c—50MHz)

<120

<120

<150

<150

<150

<150

<200

(1)  Derates same as Output Power.
(2) Current Limit is rectangular. After the overload is removed, 

output is automatically restored.

(3) See power derating curve, Figure 4.

(4) Peak current and thermal protection; applicable to 24V model only. 

See Figure 1 for peak power requirements.

(5) Ripple and noise will be approximately 1.5 times higher when 

operating temperature range is between –10°C to 0°C.

Summary of Contents for HSF 3.3-20PFC

Page 1: ...ard models and Section IV on page 6 suffix C T X and Y OPTIONS Options are identified by suffix T PFCT offers improved efficiency and less weight C PFCC offers current monitoring via an integral curre...

Page 2: ...se line ac input line failure etc results in an alarm All models include an isolated internal relay offering nor mally closed and normally open contacts referenced to an isolated common These contacts...

Page 3: ...e operating at between 10 to 100 of rated output current If current to the load goes below 10 for each unit in cur rent share mode all MASTER ON lights may go on see load effect specifications this in...

Page 4: ...emperature effects 0 9 typ 1 8 max Time Effect 1 2 hr 8 hr at 25o C 0 2 typ 0 5 max RECOVERY CHARACTERISTICS A step load change from 50 to 100 produces less than 4 output excursion Recovery occurs to...

Page 5: ...c SAFETY Units are designed to meet UL60950 3rd Edi tion CSA 22 2 No 60950 60950 1 and EN60950 and are CE marked per the Low Voltage Directive LVD 73 23 EEC and 93 68 EEC The standards do not apply wi...

Page 6: ...rature effects 0 9 typ 1 8 max Time Effect 1 2 hr 8 hr at 25o C 0 2 typ 0 5 max TABLE 2 OUTPUT RATINGS AND SPECIFICATIONS HSF PFC 100W SERIES SUFFIX C T X Y ONLY MODEL HSF 3 3 25 1 2 7 PFCC PFCT PFCX...

Page 7: ...TION RESISTANCE Between input and ground output and ground input and output 100 Megohms min 500V d c LEAKAGE CURRENT per IEC 950 and UL 1950 0 13mA typ 0 19 mA maximum 120V a c 0 45 mA maximum 240V a...

Page 8: ...TION DO NOT repeatedly toggle the POWER on off switch as this may cause unit to fault When output voltage is available the green VDC ON LED is on While monitoring output voltage at the front panel tes...

Page 9: ...ORD AVENUE FLUSHING NY 11355 U S A TEL 718 461 7000 FAX 718 767 1102 http www kepcopower com email hq kepcopower com 083013 228 1533 REV 15 9 FIGURE 6 HSF PFC 100W INCLUDING SUFFIX C T X AND Y POWER S...

Reviews: