18
POSSIBLE COMMANDS:
Each command must be followed by a carriage
return for execution.
DXX: (device “unit ID” #)- Unit XX will come “on
line” and stay “on line” until another device
is addressed.
SD XX: (set device “unit ID”#)- sets unit ID # at
requested value
ED: (examine device)- Unit will transmit the present
device (unit ID) number (i.e. d = 000000XX).
SC XXXXXX: (set count)- Sets count at requested
value.
EC: (examine count)- Unit will transmit the present
count value ( i.e. c=00XXXXXX).
RC: (reset count)- Resets the counter and control
output .
ER: (examine rate)- Unit will transmit the present
rate value (i.e. r= 000XXXXX).
RR: (reset rate)- Resets the normalization
EP: (examine peak)- Unit will transmit the present
peak value (i.e. p= 000XXXXX).
RP: (reset peak)- Unit will reset the peak.
EV: (examine valley)- Unit will transmit the present
valley value (i.e. v=000XXXXX).
RV: (reset valley)- Resets the valley.
SA XXXXX: (set preset A)- Sets preset A at re-
quested value.
EA: (examine preset A)- Unit will transmit present
preset A value (i.e. a=000XXXXX).
SB XXXXX: (set preset B)- Sets preset B at re-
quested value.
EB: (examine B)- Unit will transmit present preset
B value (i.e. b = 000XXXXX).
SL XXXXX: (set “Low”)- Sets “set low” at re-
quested value.
EL: (examine “Low”)- Unit will transmit present “set
low” value (i.e. l = 000XXXXX).
SH XXXXX: (set “High”)- Sets “set high” at re-
quested value.
EH: (examine “High”)- Unit will transmit present
“set high” value. (i.e. h = 000XXXXX)
SJ XXXXX: (set “low out”)- Sets “out low” at
requested value. Only available with ANA-
LOG OUT option.
EJ: (examine “low out”)- Unit will transmit present
“out low” value. (i.e. j = 000XXXXX)
SK XXXXX: (set “high out”)- Sets “out high” at
requested value. Only available with ANA-
LOG OUT option
EK: (examine “high out”)- Unit will transmit present
“out high” value. (i.e. k = 000XXXXX)
SN XX.X: (set norm)- Sets “norm” at requested
value. Must be a 3-digit number with
decimal.
EN: (examine norm)- Unit will transmit present
“norm” value (i.e. n = 000XX.X).
SE i 4-20, i 0-20, e 0-5, e 1-5 or e 0-10: (set input)-
sets input to one of the 4 available types.
Enter type exactly as it appears on the
display.
EE: (examine input)- Unit will transmit input type
(i.e. e 0-10).
SG XXXXX: (set dur A or hys A)- Sets dur A or hys
A at requested value. (dur A when A is
assigned to total; hys A when A assigned to
rate).
EG: (examine dur A or hys A)- Unit will transmit
present dur A or hys A value (i.e.g =
000XXXXX)
SI XXXXX: (set dur B or hys B)- Sets dur B or hys
B at requested value. (dur B when B is
assigned to total; hys B when B assigned to
rate).
EI: (examine dur B or hys B)- Unit will transmit
present dur B or hys B value (i.e.I =
000XXXXX)
SM secs, mins or hours: (set time base)- Sets
time base to desired setting.
EM: (examine time base)- Unit will transmit present
time base (i.e. secs).
ST XXXX: (set baud)- Sets baud at desired rate
(9600, 2400, 1200 or 300).
ET: (examine baud)- Unit will transmit present
baud rate (i.e. 9600).
EW: (examine lock type)- unit will transmit present
lock type (i.e. lc pg).
SX linear or sqrt: (set meter type)- Sets meter
input for linear or square root extraction.
Only available with square law option.
EX: (examine meter type)- Unit will transmit present
meter type (i.e. linear).
SY A tot or A rate: ( set A type)- Assigns control
output A to rate or total.
EY: (examine A type)- Unit will transmit present A
type (i.e. a tot).
SZ B tot or B rate: ( set B type)- Assigns control
output B to rate or total.
EZ: (examine B type)- Unit will transmit present B
type (i.e. b tot).