17
COMMANDS:
Each command consists of an instruction and
an address. Each instruction and address is
represented by a letter. The prefix of each
command must be an instruction followed by
an address (and address variable if appli-
cable).
INSTRUCTIONS (1st letter of command):
[S] Set - Used to set the value or operating
parameter of an address. (i.e. “SC 5000” will
set the count at 5000)
[E] Examine - Used to examine the value or
status of an address. (i.e. “ER” will examine
the present rate reading)
[R] Reset - Used to reset the count & control
output, peak or valley. (i.e. “RP” will reset the
peak value)
[G] Lock - used to lock and unlock the unit.
Type “G” followed by the “lock code” to lock
and unlock the unit.
[L]*List - Used to set the print list. (i.e. “LCRVA”
will set the list for count, rate, valley and preset
A. These values will be transmitted whenever
the strobe is activated.)
ADDRESSES (2nd letter of command):
[C]*Count
[R]*Rate
[P]*Peak
[V]*Valley
[A]*PreA
[B]*PreB
[L]*Lo Set
[H]*Hi Set
[J] Lo Out
[K] Hi Out
[N] Norm
[D] Unit
[E] Input
[G] Dur A
[I] Dur B
[M] Time
[T] Baud
[W] Lock
[X] Meter
[Y] A Type
[Z] B Type
[O] Code
[F] RDec
[Q] TDec
[U] TFact