11
PRESS
DISPLAY
REMARKS
input
RELAYS
A RATE
or
A ToT
(IF TOT SELECTED)
DuR A
(hit any key to view or
change existing dur A
value XX.X)
(IF RATE SELECTED)
HYS A
(hit any key to view or
change existing HyS A
value XXXXX)
B RATE
or
B ToT
(IF TOT SELECTED)
DuR B
(IF RATE SELECTED)
HYS B
STEP
2
SETTING
RELAYS
PRGM
PRGM
ENTER
ENTER
ENTER
ENTER
ENTER
ENTER
NOTE: If relay outputs
are not used,
set dur A &
dur B at "0.0"
to prevent the
counters from
resetting at the
presets.
This section of the menu sets up the
open collector outputs and/or relays.
Output A assigned to the rate or total.
Press the PRGM key to toggle be-
tween choices, press the RST/ENTER
key to enter the displayed choice.
dur A = the duration of time (.01 to
599.99 sec) that output A will remain
on or energized. When dur A is dis-
played, hit any key to view or change
dur A. Press the RST/ENTER key to
enter displayed value. When dur A is
set at 0.00,output A will latch until re-
set; when dur A is set other than 0.00
the counter will autorecycle at Preset
A.
Hys (hysteresis)= The number of units
below the preset that the output will
remain "ON". EXAMPLE: Preset set
@ 100; HyS set @ 10. Output will
activate (turn on) when rate = 100 and
turn off when rate falls below 90 (10
below preset).
Follow instructions for A RATE & A
TOT.
Follow instructions for dur A
Follow instructions for hys A
Summary of Contents for INT-69R
Page 4: ...THIS PAGE IS BLANK...