98
TS-2000/X
Required Test Equipment
1. DC Voltmeter (DC V.M)
1) Input resistance : More than 1M
Ω
2) Voltage range : 1.5 to 1000V AC/DC
Note :
A high-recision multimeter may be used. How-
ever, accurate readings can not be obtained for high-
impedance circuits.
2. DC Ammeter
1) Current range : 100mA, 1.5A, 15A, high-precision am-
meter may be used.
3. RF VTVM (RF V.M)
1) Input impedance : 1M
Ω
and less than 3pF, min.
2) Voltage range : 10mV to 300V
3) Frequency range : 10kHz to 500MHz
4. AF Voltmeter (AF V.M)
1) Frequency range : 50Hz to 10kHz
2) Input resistance : 1M
Ω
or greater
3) Voltage range : 10mV to 30V
5. AF Generator (AG)
1) Frequency range : 200Hz to 5kHz
2) Output : 1mV or less to 1V, low distortion
6. AF Dummy Load (DM. SP)
1) Impedance : 8
Ω
2) Dissipation : 3W or greater
7. Oscilloscope
Requires high sensitivity, and external synchronization
capability (150MHz or greater).
8. Sweep Generator (Sweep G.)
1) Center frequency : 50kHz to 140MHz
2) Frequency deviation : Maximum
±
35kHz
3) Output voltage : 100mV or greater
9. Standard Signal Generator (SSG)
1) Frequency range : 50kHz to 60MHz
2) Output : –133dBm/0.1
µ
V to 7dBm/1V
3) Output impedance : 50
Ω
4) AM and FM modulation can be possible
Note :
Generator must be frequency stable.
10. Frequency Counter (f. counter)
1) Minimum input voltage : 50mV
2) Frequency range : 150MHz or greater
11. Noise Generator (Noise G.)
Must generate ignition noise containing harmonics
beyond 30MHz.
12. RF Dummy Load
1) Impedance : 150
Ω
and 50
Ω
2) Dissipation : 150W or greater
13. Linear Detector
1) Frequency range : 60MHz or greater
14. Power Meter
1) Impedance : 50
Ω
2) Dissipation : 300W continuous or greater
3) Frequency limits : 60MHz or greater
15. Spectrum Analyzer
1) Frequency range : 100kHz to 140MHz or greater
2) Bandwidth : 1kHz to 3MHz
16. Detector
1) For adjustment of BPF
2) For adjustment of PLL/VCO BPF
17. Directional Coupler
18. Monitor Receiver
R-1000 class
19. Microphone
MC-43S or MC-60S8
20. Tracking Generator
21. Distortion Meter
22. Double Signal Pad (50
Ω
)
ADJUSTMENT
IN
IN
OUT
OUT
To RF unit
To Oscilloscope
10P
1N60
56
1N60
100P
IN
IN
OUT
OUT
To PLL unit
To Oscilloscope
5P
1N60
1N60
100P
Summary of Contents for TS-2000
Page 132: ...TS 2000 X TS 2000 X 134 WIRING ...
Page 142: ...1 2 B A D F C E G I H J 3 5 7 9 4 6 8 10 12 14 11 13 TS 2000 X CIRCUIT DIAGRAM 165 ...
Page 144: ...1 2 B A D F C E G I H J 3 5 7 9 4 6 8 10 12 14 11 13 TS 2000 X CIRCUIT DIAGRAM 169 ...
Page 167: ...234 TS 2000 X MC 52DM MULTI FUNCTION MICROPHONE WITH DTMF Schamatic Diagram ...