ADJUSTMENT
Measurement
Test-
equipment
Unit
Terminal
Adjustment
Unit
Parts
Method
Specifications/Remarks
Condition
Item
106
TS-2000/X
6. MAIN
1) Trap default
Tracking
Rear
ANT430 TX-RX2 TC9
Adjust the trimmer
UHF BPF
generator
panel
(A/11)
to get a null point at
366MHz as shown.
Spectrum
TX-RX2 CN19
analyzer
(A/11)
2) Menu No. : 06
Front
[+] key After setting the
Display f. : 440MHz
panel
or
adjustment value to
Spectrum analyzer setting
[–] key 145, adjust each
Center f. : 440.000MHz
TX-RX2 TC1
trimmer to obtain
Frequency span : 100MHz
(A/11)
TC2
the frequency
XdB/DIV : 5dB
TC3
response as shown.
RBW : 100kHz
VBW : 30kHz
3) Menu No. : 07
Front
[+] key Change the adjust-
Display f. : 449.8MHz
panel
or
ment values to get
[–] key the highest peak
points as shown.
4) Menu No. : 08
Display f. : 430MHz
5) Menu No. : 09
Display f. : 420MHz
7. HF RX
1) Display f. : 14.201MHz
SSG
Rear
ANT1
TX-RX1 L69
AF output max.
IF gain
Mode : USB
panel
(A/9)
L71
PRE-AMP : OFF
Oscilloscope
EXT. SP
L613
AF output : 0.63V/8
Ω
AF V.M
L614
SSG f. : 14.201MHz
DM. SP
L87
SSG output : –113dBm/0.501
µ
V
8. 1st mixer
1) Display f. : 100kHz
VR1
Noise min.
balance
Mode : USB
PRE-AMP : OFF
SSG output : OFF
9. Gain balance 1) Display f. : 9.000MHz
VR4
Set the AF output
Mode : USB
voltage to 0.63V at
SSG f. : 9.001MHz
8,999.99kHz. Then
SSG output : –116dBm/0.35
µ
V
adjust VR4 to obtain
the voltage 0.63V at
9.000MHz when the
transceiver is in the
receive mode.
(If you would not
get the specified
voltage, adjust
3. MCF and
4. MCF again.)
440MHz
449.8MHz
430MHz
420MHz
366MHz
Summary of Contents for TS-2000
Page 132: ...TS 2000 X TS 2000 X 134 WIRING ...
Page 142: ...1 2 B A D F C E G I H J 3 5 7 9 4 6 8 10 12 14 11 13 TS 2000 X CIRCUIT DIAGRAM 165 ...
Page 144: ...1 2 B A D F C E G I H J 3 5 7 9 4 6 8 10 12 14 11 13 TS 2000 X CIRCUIT DIAGRAM 169 ...
Page 167: ...234 TS 2000 X MC 52DM MULTI FUNCTION MICROPHONE WITH DTMF Schamatic Diagram ...