TK-5310
57
Measurement
Adjustment
Item
Condition
Test-
Unit
Terminal
Unit
Parts
Method
Specifications/Remarks
equipment
ADJUSTMENT
10.DTMF
1) Adj item:[W DTMF Dev]
Power meter Panel
ANT
Panel
[C],[D]
3.0kHz
±50Hz
deviation
Adjust:[***]
Deviation
Universal
adjust
Deviation meter filter
meter
connector
•Wide
LPF:15kHz
Oscilloscope
(Concentric SW:A)
HPF:OFF
AG
PTT:ON
AF VTVM
Press [B] to store the adjustment
value after adjustment.
•Narrow
2) Adj item:[N DTMF Dev]
Set it to the adjustment
(Concentric SW:B, C)
value obtained from
the [W DTMF Dev]
adjustment of a step
1), using the [C] and
[D] keys.
After setting the
adjustment value,
press [B] key.
The adjustment
value will be stored
in memory.
11.Single tone
1) Adj item:[W Tone Dev]
Panel
[C],[D]
3.0kHz
±50Hz
deviation
Adjust:[***]
adjust
Deviation meter filter
•Wide
LPF:15kHz
(Concentric SW:A)
HPF:OFF
PTT:ON
Press [B] to store the adjustment
value after adjustment.
•Narrow
2) Adj item:[N Tone Dev]
Set it to the adjustment
(Concentric SW:B, C)
value obtained from
the [W Tone Dev]
adjustment of a step
1), using the [C] and
[D] keys.
After setting the
adjustment value,
press [B] key.
The adjustment
value will be stored
in memory.