TK-5310
49
ADJUSTMENT
ADJUSTMENT
11 : GREEN (5M)
TUBE
SCREW
8 : YELLOW (PF SW)
2 : RED (RX AF OUTPUT)
3 : BLACK (RX AF OUTPUT)
10 : BROWN (GND)
6 : BROWN (MIC GND)
5 : WHITE (MIC INPUT)
7 : BLUE (PTT SW) GND
→
ON
RED (2)
BLK (3)
100
µ
10V
100
µ
10V
8
Ω
WHT
(5)
BRN (6)
BLU (7)
BRN (10)
PTT SW
+
+
+
To transceiver
AF Voltmeter
Audio generator
10
µ
10V
3. Universal connector
Use the interface cable (KPG-36/36A) for PC tuning or the
lead wire with plug (E30-3287-18) and screw (N08-0535-08)
for panel tuning. Connect the plug to the universal connector
of the transceiver and tighten the screw.
The lead wire with plug (E30-3287-18) and screw (N08-
0535-08) terminals are as follows. Numbers are universal
connector terminal numbers.
Caution
1. When connecting the plug to the universal connector of
the transceiver, a short circuit may occur. To prevent this,
be sure to turn the transceiver POWER switch off.
2. Since the RX AF output is a BTL output, there is a DC
component. Isolate this with a capacitor or transformer as
shown in the figure.
3. Do not connect an instrument between red or black and GND.
• Universal connector
• Panel tuning
1 : SSW
3 : SP–
5 : EMC
7 : PTT
9 : OPT
11 : 5M
13 : RXD
2 : SP+
GND
EXT ANT
GND
4 : MSW
6 : ME
8 : PF
10 : E
12 : TXD
14 : NC
• PC tuning
Connect the wires to the PCB in the connector case of
interface cable.
For output the wires out of the connector case, need to
process the connector case.
Connector case
KPG-36/36A
Remove the
screw
PCB layout
Shield
AF voltmeter
Audio generator
100
µ
10V
100
µ
10V
10
µ
10V
+
+
+
8
Ω
How to Remove the Flat Cable
1. Gently draw out both sides of the connector lever uni-
formly in the direction of the arrow with tweezers.
(CN606, CN613, CN800, CN802, CN803, CN804)
CN613, CN800, CN802: K2, K3, K5 and K6 models only
Tweezers
Flat cable
Lever
Summary of Contents for TK-5310