TK-5310
53
4. 2nd local
1) Adj item:[2nd Lo Freq]
f.counter
TX-RX
2nd Lo
Panel
[C],[D]
Change the
50.400MHz ±50Hz
adjust
Adjust:[***]
(A/5)
adjustment value
Press [B] to store the adjustment
within the limit of
value after adjustment.
the specified
frequency.
5. RTC
1) CH-Sig:1-1
f.counter
TX-RX
CLKC
Programming Adjust the RTC
oscillation
DVM
(A/5)
32kout
Software:
oscillation frequency
frequency
DC power
KPG-95D using the PC tuning
adjust
supply
mode. Perform the
procedures below.
1. Apply 5V DC to
the "CLKC" terminal
of the TX-RX unit
(X57-725) (A/5).
2. Measure the output
from the "32kout"
terminal of the TX-RX
unit (X57-725) (A/5)
using the calibrated
frequency counter.
3. Enter the measured
frequency value to
"Crystal Oscillation
Frequency" of RTC
correction in the PC
tuning mode and then
click [OK] button.
6. LCD
1) CH-Sig:1-1
Programming Adjust the LCD
Note: Because the
contrast
Software:
contrast using the transceiver has a
adjust
KPG-95D PC tuning mode.
function for revising a
change in temperature,
Slide the bar to adjust adjust the LCD contrast
the value. The larger at room temperature
the value, the darker (18 to 28 degrees).
the LCD becomes;
the lower the value,
the more transparent
the LCD becomes.
Measurement
Adjustment
Item
Condition
Test-
Unit
Terminal
Unit
Parts
Method
Specifications/Remarks
equipment
ADJUSTMENT
Note: It is not necessary
to adjust the RTC
oscillation frequency under
normal adjustments.
The RTC oscillation frequency
must be checked and
adjusted when the 32 kHz
crystal resonator (X1) is
replaced.
(Refer to
“Adjustment
Points” des-
cribed on
page 47.)
Summary of Contents for TK-5310
Page 96: ...TK 5310 91 MEMO ...